Amana xMVM97 series Installation Instructions Manual page 40

Modulating gas furnace
Table of Contents

Advertisement

Low
Model
Tap
Stage
Cool
A
398
B
557
*MVM970603BN*
696
C
810
D
A
403
540
B
*MVM970803BN*
705
C
D
819
513
A
660
B
*MVM970804CN*
C
791
913
D
564
A
B
784
*MVM971005CN*
982
C
1259
D
A
547
831
B
*MVM971205DN*
1020
C
D
1278
433
A
541
B
*CVM970603BN
C
686
806
D
A
405
B
549
*CVM970803BN
C
678
D
784
556
A
714
B
*CVM970804CN*
838
C
D
991
524
A
744
B
*CVM971005CN*
C
927
1185
D
*1 00% CFM shown. CFM will vary pro portio nally with the gas valve B TU/H input.
4. Continuous fan speed is selectable at 25%, 50%, 75% or
100% of the furnace's maximum airflow capability.
Example:
If the furnace's maximum airflow capability
is 2000 CFM, the continuous fan speed at
25% will be 0.25 x 2000 or 500 CFM.
5. Locate the blower speed selection DIP switches on the
integrated control module. Select the desired "cooling"
speed tap by positioning switches 1 and 2 appropriately.
Select the desired "adjust" tap by positioning switches 9
and 10 appropriately. Refer to the DIP switch chart for
switch positions and their corresponding taps. Verify CFM
by noting the number displayed on the dual 7-segment
LED display.
40
100%
Low heat
High Stage
Heat
CFM for
Cool
*CFM
2 stage
599
953
667
817
1059
740
1007
1158
808
1212
1260
881
629
1202
855
806
1316
923
1023
1389
1033
1230
1396
1063
789
1228
867
967
1337
939
1182
1430
1016
1375
1516
1077
820
1818
1256
1133
1870
1292
1464
1910
1316
1736
1957
1358
867
1891
1329
1160
1940
1362
1467
1968
1390
1910
2028
1440
656
938
687
790
950
751
972
986
814
1195
992
874
624
1057
758
808
1146
815
994
1256
882
1177
1349
946
837
1234
889
1022
1325
944
1206
1442
1019
1475
1528
1068
784
1759
1209
1078
1797
1249
1388
1840
1277
1766
1881
1300
6. The multi-speed circulator blower also offers several
custom ON/OFF ramping profiles for cooling. These
profiles may be used to enhance cooling performance
and increase comfort level. The ramping profiles are
selected using DIP switches 7 and 8. Refer to the
bullet points below for a description of each ramping
profile. Verify CFM by noting the number displayed on
the dual 7-segment LED display.
• Profile A provides only an OFF delay of one (1) minute at
100% of the cooling demand airflow.
100% CFM
OFF
Figure 52A
• Profile B ramps up to full cooling demand airflow by first
stepping up to 50% of the full demand for 30 seconds.
The motor then ramps to 100% of the required airflow. A
one (1) minute OFF delay at 100% of the cooling airflow is
provided.
100% CFM
50% CFM
OFF
1/2 min
Figure 52B
• Profile C ramps up to 85% of the full cooling demand airflow
and operates there for approximately 7 1/2 minutes. The
motor then steps up to the full demand airflow. Profile C
also has a one (1) minute 100% OFF delay.
OFF
Figure 52C
• Profile D ramps up to 50% of the demand for 1/2 minute,
then ramps to 85% of the full cooling demand airflow and
operates there for approximately 7 1/2 minutes. The
motor then steps up to the full demand airflow. Profile D
has a 1/2 minute at 50% airflow OFF delay.
OFF
Figure 52D
Airflow Tables
100% CFM
OFF
1 min
100% CFM
OFF
1 min
100% CFM
OFF
OFF