1. Remove the Control board cover. (Fig.4)
2. Remove the screw at the control board then pull out the control board. (Fig.5)
3. Release CN-TH from evaporator. (Fig.5)
4. Release earth wire screw from the evaporator. (Fig.5)
5. Disconnect below connectors from PCB. (Fig.5)
• Terminal FG GRN.
• CN-STM1 - Air Swing Motor for vertical louver.
• CN-STM2 - Air Swing Motor for horizontal louver.
• CN-FM - Indoor Unit Fan Motor.

15.1.3. Removal of PCB

1. Disconnect lead wire from terminal board complete. (Fig.6)
2. Disconnect live wire (brown) from terminal plate connector. (Fig.6)
3. Release screw from the control board. (Fig.6)
4. Remove control board cover (L) and control board cover (R) from the control board. (Fig.6)
5. Remove control board cover (R) from control board cover (L) by releasing the hooks. (Fig.7)