Natural Gas; Propane/Lpg; Specifications; Ignition Controls - Monessen Hearth DIS33 Installation And Operating Instructions Manual

Natural gas or propane/lpg control type: milli-volt, t-stat, or hi/lo remote control vent-free fireplace systems
Table of Contents

Advertisement

PRODUCT FEATURES

NATURAL GAS

Milli-Volt and T-Stat Pressure
Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator: 3.5" w.c.
Gas Inlet Pressure: Max. 10 1/2" w. c.
Min. 5" w.c.
Model Number
DIS33NTC
DIS33NVC
DIS33NHC

PROPANE/LPG

Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
Milli-Volt and T-Stat Pressure
Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure: Max. 13" w.c.
Min. 11" w.c.
Model Number
DIS33PTC
DIS33PVC
DIS33PHC

IGNITION CONTROLS

Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Hi/Lo valve control has four (4) positions:
OFF
- All gas to the gas logs is shut off at the valve.

PILOT

- Valve position to light/maintain a standing pilot.
ON
- Valve position to turn ON.
HI/LOW
- Variable position corresponding to desired flame height back to pilot.
Milli-Volt and T-Stat control has four (4) positions:
OFF
- All gas to the gas logs is shut off at the valve.
IGN
- Valve position to light/maintain a standing pilot.
ON
- Valve position to turn ON/OFF log set with remote switch/thermostat.
LOW/HI
- Variable position to control flame height (heat output). Both front and rear burners are in operation
to provide realistic glow and yellow flame.
PILOT
The gas log heater is fitted with a specially designed safety pilot light (ODS assembly) which senses the amount of oxygen
available in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot
can only be relit when adequate fresh air is available.

THERMAL GENERATOR

The milli-volt gas log pilot is fitted with a milli-volt generator to provide power for remote activation.
6

SPECIFICATIONS

AND
Hi/Lo Pressure
Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator: 3.5" w.c.
Gas Inlet Pressure: Max. 11" w.c.
Control
MILLI-VOLT
T-STAT
HI/LO REMOTE
Hi/Lo Pressure
Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure: Max. 13: w.c.
Control
MILLI-VOLT
T-STAT
HI/LO REMOTE
Min. 6" w.c.
Gas Rate
Max BTU/Hr
Min BTU/Hr
28,000
28,000
28,000
Min. 12" w.c.
Gas Rate
Max BTU/Hr
Min BTU/Hr
28,000
28,000
28,000
18,000
18,000
18,000
20,000
20,000
21,000
26D3311