Chapter 2
Rack Installation Specifications
2.1
Rack Installation Requirements
ETERNUS DX500 S3 Connection Example
Installing 2U DEs in the Same Rack
This section describes a connection configuration in which all of the enclosures are installed in the same
rack.
The following figure shows an example when one controller enclosure and 14 drive enclosures (2U) are in-
stalled in a rack.
For this type of configuration, the length of cables that are provided with the drive enclosures is not enough
to connect the enclosures. Obtaining extra extension cables for reverse cabling to connect the controller en-
closure to the last drive enclosure is required.

Figure 2.2 Connection Example 1 (ETERNUS DX500 S3 Connections in the Same Rack)

Cables that are supplied as standard
1.1m
Extension cables
2.5m
FUJITSU Storage ETERNUS DX500 S3/DX600 S3 Disk storage system Site Planning Guide
DE#16 (2U)
DE#06 (2U)
DE#15 (2U)
DE#05 (2U)
DE#14 (2U)
DE#04 (2U)
DE#13 (2U)
DE#03 (2U)
DE#12 (2U)
DE#02 (2U)
DE#11 (2U)
DE#01 (2U)
DE#10 (2U)
DE#00 (2U)
CE
40
Copyright 2014 FUJITSU LIMITED
P3AM-7712-05ENZ0