Flow Of Functional - JVC MX-K1 Service Manual

Compact component system
Hide thumbs Also See for MX-K1:
Table of Contents

Advertisement

MX-K1
Flow of functional operation until TOC read
Power ON
Tracking error waveform at TOC reading
Approx.3sec
pin 20 of
IC611(TE)
Approx
1.8V
VREF
Tracking
servo
off states
Disc states
to rotate
Automatic measurement
of TE amplitude and
automatic tuning of
TE balance
1-20
Play Key
Automatic tuning of
Automatic measurement of
Focus S-curve amplitude
Automatic measurement of
Tracking error amplitude
Tracking
Disc to be
servo
braked to stop
on states
Automatic tuning of
TOC reading
finishes
Tracking error balance
500mv/div
2ms/div
Fig.1
Slider turns REST
SW ON.
Automatic tuning
of TE offset
Laser ON
Detection of disc
Focus offset
Disc is rotated
Focus servo ON
(Tracking servo ON)
Automatic tuning of
Focus error balance
Automatic tuning of
Focus error gain
Automatic tuning of
Tracking error gain
TOC reading
Play a disc
Check Point
Confirm that the voltage at the pin5
of CN602 is "H"\"L"\"H".
Check that the voltage at the
pin40 of IC601 is + 5V?
Confirm that the Focus error
S-cuve signal at the pin32 of
IC601 is approx.2Vp-p
Confirm that the signal from
pin24 IC601 is 0V as a
accelerated pulse during
approx.400ms.
Confirm the waveform of
the Tracking error signal.
at the pin 20 of IC611 (R643)
(See fig-1)
Confirm the eys-pattern
at the lead of TP3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp-mxk1Ca-mxk1

Table of Contents