Chart For The Water/Service Test - Frigidaire Fully Integrated Direct FeedModel Dishwashers Service Manual

Fully integrated direct feed model dishwashers
Table of Contents

Advertisement

DESCRIPTION
FILL/DISPENSER
FILL
WASH/HEAT (3450rpm)
PAUSE
WASH/HEAT (2800rpm)
WASH/HEAT/DISP (3450rpm)
DRAIN
DRY
TOTAL
SANITIZE and CLEAN LED stay on until door is opened or cycle started.
If the rinse agent is low in the dispenser LO will be displayed in the front display.
Relay/ Triac and Sensor Test
This test allows the servicer to troubleshoot the
dishwasher by energizing the different devices of the
dishwasher independently from one another. The
best way to understand the value of this test for field
service technicians is the example of testing the
heater for operation. Enter the test followed by
pressing pad number 10 on the keypad (see table)
this will apply power to the heater. The heater will be
powered until the same pad is pressed a second
time.
This test can only be entered from a PF (Power
Failure) condition. This can be accomplished in two
ways. First is to have the power removed from the
dishwasher then turned back on this will show a PF
in the display and the test can be entered.
Chart For the Water Service Test
60 1
0
0
0
27 1
0
0
0
45 0
1
0
1
0.4 0
0
0
1
75 0
1
0
1
60 0
1
0
1
90 0
0
1
0
90 0
0
1 X 0
447
X- denotes a selectable option
1
0
1
0
0
0
0
0
1
0
0
0
0
0
1
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
1
0
0
1
0
0
0
1
0
1
0
0
1
0
0
1
0
0
0
0
1
The second method to enter this test is to program
the control into a Water/Test, at the completion of
this test then open the door the control goes into a
PF condition now program the Relay/Triac test. By
going through the water test you do not have to
disconnect power to the unit and the test can be
entered rather quickly.
To access this test the unit must be placed in PF
condition. While in PF press and hold Pad # 1 and
Pad # 7 at which time an "rt" will appear in the
display. You can now follow the chart below as to
how to select the component to operate. While in this
test if you wish to test more then one component you
must always repress the previously selected pad to
leave one component before moving on two the next.
When the tests are completed you must again Press
Pad # 1 and the Pad # 7 this will return you to PF
mode.
17
Device
being
monitored
1
0 fan damper uo
1
0 turbidity
tu
1
0 hall sensor
hs
1
0
0
0
0
0 thermistor
th
0
0 fan speed
uF
0
0 rinse aid
rA
0
1