Continuous Dispensing Timer (S1 Dip Switch 5 & 6); Bin Control Selector (S1 Dip Switch 7); Bin Control Shutdown Delay (S1 Dip Switch 8); Factory Use (S1 Dip Switch 9 & 10) - Hoshizaki DCM-270BAH Service Manual

Cubelet icemaker/dispenser
Hide thumbs Also See for DCM-270BAH:
Table of Contents

Advertisement

4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
The factory setting allows ice to be dispensed continuously for 20 sec. The DCM-270BAH
may be adjusted to other dispense time options.
NOTICE! On DCM-270BAH-OS, do not adjust S1 dip switch 5 & 6 out of the factory
default position.
Note: The ice dispense solenoid has an internal overload protector. When set to "No
Limit" the internal protector may open if ice dispense solenoid is energized longer than
3 to 4 min. at one time.

5. Bin Control Selector (S1 dip switch 7)

The appliance is factory set with mechanical bin control operation. No adjustment is
required. In the factory default position (S1 dip switch 7 in the off position), the gear
motor delay after the upper float switch closes is 5 seconds. WARNING! Do not adjust
S1 dip switch 7 out of the factory default position. This dip switch must be left in
the factory default position or the appliance will not operate correctly.
S1 Dip Switch
Setting
No. 7
OFF
Bin Control (Mechanical)
Bin Control (Infrared Sensor) with
ON
Mechanical Bin Control Backup
6. Bin Control Shutdown Delay and Storage Bin Agitation Timer (S1 dip switch 8)
Factory set for normal operation. No adjustment is required. The shutdown delay is the
time between the bin control microswitch opening and the control board shutting off the
appliance. A 2-second periodic agitation occurs every 90 minutes.
7. Factory Use (S1 Dip Switch 9 & 10)
Factory set for optimum performance. Do not adjust.
S1 Dip Switch Setting
No. 5
No. 6
OFF
OFF
ON
OFF
OFF
ON
ON
ON
Bin Control Application
S1 Dip Switch
Bin Control #1
Setting
Shutdown Delay
No. 8
OFF
0.25 Seconds
ON
6.7 Seconds
Dispense Time
No Limit
20 Seconds
60 Seconds
No Limit
Storage Bin
Periodic Agitation
2 Seconds
No Agitation
34
Gear Motor Delay
5 seconds
30 seconds

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcm-270bah-os

Table of Contents