MULTIQUIP ga2.5Hr Operation And Parts Manual page 36

Honda gx160rt2eman gasoline engine
Table of Contents

Advertisement

GA2.5HR — NAMEPlATE AND DECAlS ASSy.
QUARTZ
120
9
DANGER
WARNING
Do not touch output terminals or
To avoid injury,
internal wiring while unit is operating.
you MUST read
Turn off power before servicing.
S-4985
and understand
Only qualified personnel should
ELECTRICAL
operator's manual
SHOCK
install, use or service this
equipment.
HAZARD
before using this
machine.
WARNING
This machine to
be operated by
Only operate machine in well ventilated
qualified
areas.
personnel only.
DO NOT inhale exhaust gases.
Ask for training
Only qualified personnel should
S-4984
as needed.
install, use or service this
Only qualified personnel should
DANGEROUS
install, use or service this
equipment.
GAS
equipment.
13
NEVER use in enclosed or partially
enclosed areas.
Utilisation INTERDITE dans un
espace clos ou partiellement clos.
pAgE 36 — ga2.5HR 60 hz gENERATOR• OpERATiON ANd pARTs mANuAl — REv. #0 (12/15/14)
1
GA-2.5HR
20A
V
120
GFCI PROTECTED
120V
4
2.5kW
CAUTION
OPERATE AT
3600 RPM ONLY
(
)
FULL THROTTLE
DAMAGE MAY RESULT IF
OPERATED AT LOWER SPEEDS
WARNING
B e f o r e c o n n e c t i n g t h i s
g e n e r a t o r t o a n y b u i l d i n g ' s
e l e c t r i c a l s y s t e m , a l i c e n s e d
e l e c t r i c i a n m u s t i n s t a l l a n
i s o l a t i o n ( t r a n s f e r ) s w i t c h .
S e r i o u s i n j u r y o r d e a t h m a y
r e s u l t w i t h o u t t h i s t r a n s f e r
s w i t c h .
A91110010
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES.
Utilser un générateur à l' intérieur VOUS TUERA EN QUELQÙES MINUTES.
Exhaust contains carbon monoxide, a poison gas you cannot see or smell.
Les gaz d' échappement contiennent du monoxyde de carbon, un gaz toxique
invisible et inodore.
GAC-2.2H
POWERED by
11250AV
120
ASISS A
V
NEUTRAL BONDED TO FRAME
LNAE UCTARREC M
R
E LDAU M
MAOSTSEEU A
GAC-2.2H
11250AV
NEUTRAL BONDED TO FRAME
V
120
211052
GR TPERRISREE DE
Honda Engines
IO N U
ACR
A
TIT
CC
R
C
IRR
TE
NUU
CA ID
IU N ER
RER
EL R
E
P TB
P
P
KA
GR TPERRISREE DE
211052
Honda Engines
POWERED by
CC
IO N U
A
C
TE
R
LNAE UCTARREC M
ACR
IRR
R
MAOSTSEEU A
KA
ASISS A
P
E LDAU M
E
TIT
NUU
RER
EL R
P TB
CA ID
IU N ER
P
GAC-2.2H
211052
Honda Engines
POWERED by
11250AV
LNAE UCTARREC M
NEUTRAL BONDED TO FRAME
IRR
C
A
120
V
R
KA
EL R
MAOSTSEEU A
ASISS A
E LDAU M
GR TPERRISREE DE
TE
ACR
CC
R
IO N U
NUU
E
CA ID
P
IU N ER
RER
P TB
P
TIT
ONLY use outdoors and away from
open windows, doors, and vents.
Utilisation UNIQUEMENT à l' extér leur
portes et trous d' aération
A90400001
Operation of this equipment may create
sparks that can start fires around dry
12
vegetation.
A spark arrestor may be required.
The operator should contact local fire
agencies for laws or regulations
relating to fire prevention requirements.
2
MODEL
SERIAL NO.
20A
AC VOLTMETER
AC CIRCUIT
BREAKER
5
AIR CLEANER MAINTENANCE
CLEAN ELEMENT EVERY 50 HOURS (EVERY
7
10 HOURS UNDER DUSTY CONDITIONS.
WASH IN HIGH FLASH-POINT SOLEVENT
SQUEEZE DRY, THE DIP IN CLEAN ENGINE
OIL AND SQUEEZE OUT EXCESS OIL.
3
S-1123
FUEL COCK
6
ON
ON
S-1407
HONDA
8
GX
160
10
OPERATING INSTRUCTIONS
1. Before starting check the oil and fuel level.
2. Switch the circuit breaker to the "OFF" position.
3. Open the fuel valve.
4. Close the choke with the choke lever.
5. Turn the operation switch to the "ON" position
6. Pull the recoil starter.
7. After the engine starts, gradually push in the choke valve.
8. Run the generator for 3-5 minutes without load.
9. Check for any abnormal noise or smell.
10.Switch the circuit breaker to the "ON" position.
11. When stopping, remove the load for 2-3 minutes before
stopping engine.
12. Turn the operation switch to the "OFF" position.
13. After the engine completely stops. Close the fuel valve.
A92120000
DANGER
THE POSSIBILITY EXISTS OF ELECTROCUTION IF
GENERATOR/WELDER IS NOT PROPERLY GROUNDED.
ALWAYS CONNECT EARTH GROUND (GROUND
ROD) TO GENERATOR GROUND POINT.
0N
6000
V
120
OFF
ON
OFF
CONTROL
IDLE
120V
OFF
21A
OPERATION
SWITCH
GROUND
BREAKER
AC CIRCUIT
120V/240V
20A
GA-6H
120/240V
120V
FULL POWER
SWITCH
30A
30A
20A
SCREW
GROUND
CABLE
#8 MINIMUM
GROUND ROD
FOR EARTH
GROUND
CONNECT TO
BUILDING
GROUND
IF REQUIRED
8 FT. MINIMUM
FOR FURTHER GROUNDING
INSTRUCTIONS, READ MANUAL
REFERENCE
NEC 250-52(C)
D9531100104