8. Place main circuit breaker (Figure 15) in the ON
position.
Figure 15. Main Circuit Breaker (ON)
9. Read voltmeter on front panel of generator (Figure 16)
and verify that 120 VAC is displayed. Using an external
voltmeter as shown in Figure 16, verify that 120 VAC
is present at the 120V twist-lock and GFCI duplex
receptacles.
W
G
120VAC
X
L5-20R
120V
120
V
Figure 16. 120V Twist-Lock/GFCI Receptacles
NOTICE
When using a combination of dual receptacles, total
load should not exceed the rated capacity of the
generator.
10. Connecting of loads (power tools, lighting etc.) to the
generator receptacles can now be done.
pAgE 24 — ga2.5HR 60 hz gENERATOR• OpERATiON ANd pARTs mANuAl — REv. #0 (12/15/14)
GFCI
120 VAC
OFF
V~
V
300 mV
A~
A
V
COM
stopping the Engine (Normal shutdown)
1. Place main circuit breaker (Figure 17) in the OFF
position.
Figure 17. Main Circuit Breaker (OFF)
2. Place the engine ON/OFF switch (Figure 18) in the
"OFF" position
Figure 18. Engine ON/OFF Switch (OFF)
3. Let engine run at idle with no load for 2-3 minutes.
4. Place engine fuel valve lever (Figure 19) in the OFF
position.
Figure 19. Engine Fuel Valve Lever (OFF)
5. Remove all loads from the generator.
Emergency shutdown
1. Place engine ON/OFF switch (Figure 18) in the OFF