Mains Electricity Connection

THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED
WIRING VIA A DOUBLE POLE SWITCHED FUSE SPUR OUTLET AND PROTECTED BY A 3A FUSE.
We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will
comply with the I.E.E. and local regulations.
The wires in the mains lead of this appliance are coloured in accordance with the following code:
Green & Yellow = Earth, Blue = Neutral, Brown = Live.
As the colours of the wires in the mains lead for the appliance may not correspond
with the coloured markings identifying the terminals connecting to the fuse spur,
proceed as follows:
The wire which is coloured green and yellow must be connected to the
terminal marked E (Earth) or coloured green.
The wire which is coloured blue must be connected to the terminal marked
N (Neutral), or coloured black.
The wire which is coloured brown must be connected to the terminal marked
L (Live), or coloured red.
Note: Use a 3A Fuse
Assembly and electrical connection should be carried out by specialised personnel.
When installing this product we recommend you seek the help of another individual.

Electrical Information

Mains electrical voltage: 230 – 240Vac, 50Hz
Total rated power consumption:
290W

Troubleshooting

If your extractor is not working:
1.
Check that the mains supply has not been switched off.
2.
Check that the fuse in the spur has not blown.
DOUBLE POLE SWITCHED
FUSE SPUR OUTLET
USE A 3 AMP FUSE