Mains Electricity Connection - CDA ECNK90 Installation, Use And Maintenance Manual

Island extractor
Table of Contents

Advertisement

Mains electricity
connection
THIS APPLIANCE MUST BE
CONNECTED TO THE MAINS SUPPLY
BY A COMPETENT PERSON, USING
FIXED WIRING VIA A DOUBLE POLE
SWITCHED FUSED SPUR OUTLET
AND PROTECTED BY A 3A FUSE.
The appliance must be connected by a
qualified electrician, who is a member
of the N.I.C.E.I.C. and who will comply with the I.E.T.
and local regulations.
The wires in the mains lead of this appliance are coloured in
accordance with the following code:
BLUE = NEUTRAL, BROWN = LIVE, GREEN+YELLOW = EARTH
As the colours of the wires in the mains lead for the appliance may
not correspond with the coloured markings identifying the terminals
connecting to the fused spur, proceed as follows:
The wire which is coloured blue must be connected to the terminal
marked N (Neutral), or coloured black.
The wire which is coloured brown must be connected to the
terminal marked L (Live), or coloured red.
The wire which is coloured green and yellow must be connected
to the terminal marked E (Earth) or coloured green or green and
yellow.
10
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
USE A 3 AMP FUSE