Toshiba RAS-22SKV2-A1 Service Manual page 52

Toshiba split type air conditioner service manual
Table of Contents

Advertisement

CAUTION
• Be sure to refer to the wiring system diagram
labeled inside the front panel.
• Check local electrical regulations for any
specific wiring instructions or limitations.
Cord clamp
Screw
Terminal cover
Screw
Connecting
cable
Stripping length of the connecting cable
Fig. 10-3-6
110mm
10mm
10mm
Fig. 10-3-7
NOTE :
WIRE TYPE :
More than 1.0mm². (H07 RN-F or 60245 IEC 66).
Terminal block
Earth line
Connecting cable
110mm
Earth line
20mm
10mm
80mm
50mm
10-3-5. Piping and Drain Hose Installation
Piping and drain hose forming
• Since condensation results in machine trouble,
make sure to insulate both the connecting pipes
separately.
(Use polyethylene foam as insulating material.)
Rear right
Rear left
Bottom left
Left
Bottom right
Right
1. Die-cutting front panel slit
Cut out the slit on the left or right side of the front
panel for the left or right connection and the slit
on the bottom left or right side of the front panel
for the bottom left or right connection with a pair
of nippers.
2. Changing drain hose
For left connection, left-bottom connection and
rear-left connection's piping, it is necessary to
relocate the drain hose and drain cap.
How to remove the drain cap
Clip drain cap with needle-nose pliers, and pull out.
How to remove the drain hose
The drain hose is secured in place by a screw.
Remove the screw securing the drain hose, then
pull out the drain hose.
Heat insulator
Drain hose
– 52 –
FILE NO. SVM-12002
Fig. 10-3-8
Fig. 10-3-9
Fig. 10-3-10