10-3. Indoor Unit

10-3-1. Installation Place
• A place which provides enough spaces around
the indoor unit as shown in the diagram.
• A place where there are no obstacle near the air
inlet and outlet.
• A place which allows easy installation of the
piping to the outdoor unit.
• A place which allows the front panel to be
opened.
• The indoor unit shall be installed so that the top of
the indoor unit is positioned at least 2 m in height.
• Also, avoid putting anything on the top of the
indoor unit.
CAUTION
• Direct sunlight on the indoor unit wireless
receiver should be avoided.
• The microprocessor in the indoor unit should
not be too close to r-f sources.
(For details, see the owner's manual.)
Remote controller
• Should be placed where there are no obstacles,
such as curtains, that may block the signal.
• Do not install the remote controller in a place
exposed to direct sunlight or close to a heating
source, such as a stove.
• Keep the remote controller at least 1 m away from
the nearest TV set or stereo equipment.
(This is necessary to prevent image disturbances
or noise interference.)
• The location of the remote controller should be
determined as shown below.
(Side view)
Reception
range
Remote controller
Fig. 10-3-1
(Top view)
Indoor unit
Reception
range
Remote controller
10-3-2. Drilling a Hole and Mounting
Installation Plate
Drilling a hole
When install the refrigerant pipes from the rear.
35
120
The center of the pipe hole is the above arrow.
1. After determining the pipe hole position on the
installation plate (
at a slight downward slant to the outdoor side.
NOTE :
• When drilling into a wall that contains a metal lath,
wire lath or metal plate, be sure to use a pipe hole
brim ring sold separately.
Mounting the installation plate
Anchor bolt holes
170
To unit out line
240mm
85
Hook
Pipe hole
Thread
Indoor unit
– 50 –
FILE NO. SVM-12002
180
240
Pipe hole
Fig. 10-3-2
ð
) drill the pipe hole (Ø65 mm)
Hook
To unit out line
240mm
To unit out line
35mm
To unit out line
120mm
240
180
35
120
0
23
Hook
Mounting
7
1
Screw
Weight
Fig. 10-3-3
23mm
Dia .65mm
170
132
23
Pipe hole (dia. 65mm)
Installation
plate