TROUBLE-
SHOOTING
Leakages occur
from the water
Sealing gasket defective or
and steam pipes
presence of a foreign body
with the relative
in the seal housing.
taps shut.
Water or steam
leakages occur
under the tap
Tap axis seals detective.
k n o b s d u r i n g
opening.
A loss between
the group and
Underpan seal detective or
the filter holder
edge of fi lter irregular.
occurs during
delivery.
Loss of water
from the group
Seal detective.
valves locking.
Loss of water
from the block
Tap axis seal detective.
ring-nut during
manual loading.
• There are residues of dirt in
the seat of the fi lter holder,
which prevent the coffee from
Coffee goes out
passing through the nozzle.
from the sides of
• The seal of the group is
fi lterholder.
worn out.
• The funnels are clogged
The coffee is too
The machine is not ready.
cold.
• Supply tap off.
Coffee is not be-
• Water supply low.
ing dispensed or
• Dispensing hole of the fi lter
it is being done
holder clogged.
too slowly.
CAUSES
SOLUTIONS FOR
THE TECHNICIAN
Check and replace if
necessary.
Check and replace if
necessary.
Replace.
Replace.
Replace.
• Clean
• Replace
• Clean or replace
Wait until the temperature is reached, shown
by the warning light going out.
•Turn on the tap.
• Check the supply line.
• Clean the fi lter holder well, using a special
detergent and a toothpick.
SOLUTIONS FOR
THE USER
Contact authorized
service agent
Contact authorized
service agent
Contact authorized
service agent
Contact authorized
service agent
Contact authorized
service agent
ENGLISH / 27