TROUBLESHOOT-
ING
The water level con-
trol provides water
when it should not
and the level gauge
light is on.
The water level con-
trol does not provide
water when it should
and the level gauge
light is off.
The water level con-
trol does not provide
water when it should
and the level gauge
light is on.
The water level in
the boiler contin-
ues to rise until it
escapes from the
safety valve.
The graduated op-
tical gauge does
not show the actual
water level in the
boiler.
The boiler gets up
to pressure but the
group will not de-
liver.
The machine will
only deliver when
the heating element
is electrically pow-
ered (red indicator
light on).
CAUSES
• The level sensor/control
centre electrical connection is
broken.
• The frame earthing/control
centre electrical connection is
broken.
• The level sensor is dirty.
• The electronic control centre
is defective.
• The sensor is touching the
glass or earthed metal parts.
• The electronic control centre
is defective.
• The loading solenoid valve
coil is broken.
• The loading solenoid valve
core is blocked.
• Level sensor not connect-
ed.
• There is a foreign body inside
the water level control solenoid
valve.
• There is a foreign body in the
seal housing.
• The seal is worn.
The gauge's lower connec-
tion pipe with the boiler is
obstructed.
• The control centre fuses are
shot (dosed version).
• The delivery switch is defec-
tive.
• The solenoid valve will not
open.
"Neutral" is missing from the
electrical power supply.
SOLUTIONS FOR
THE TECHNICIAN
• Repair.
• Repair.
• Clean; when disman-
tling do not unthread it
from the insulator but
remove it complete with
the union.
• Replace.
• Check and reposition.
• Check and replace if
necessary.
• Check and replace if
necessary.
• Check and replace if
necessary.
• Check and replace if
necessary.
• Check and replace if
necessary.
• Check.
• Check and replace if
necessary.
Dismantle and clean.
Check and replace if
necessary.
Check and reset.
SOLUTIONS
FOR THE USER
Contact authorized
service agent
Contact authorized
service agent
Contact authorized
service agent
Contact authorized
service agent
Contact authorized
service agent
Contact authorized
service agent
Contact authorized
service agent