On Finished Walls - Viessmann Vitodens 100 WB1 Technical Data Manual

Gas-fired condensing boiler 8.8 to 25.6 kw
Table of Contents

Advertisement

Installation in unfinished buildings

(on finished walls)

Pre-installation in unfinished buildings for mounting the Vitodens 100 directly on finished walls
Accessories required for installation
without a domestic hot water cylinder
Mounting aid
with fastenings, fittings and b" dia. gas
cock with a built-in thermal safety shut-
off valve
D
The drawing shows the connections required for the gas combination boiler
Legend
E
Drain
GA
Gas connection b"
HR
Heating return c"
HV
Heating flow c"
OKFF Finished floor level
6
Additional accessories required for con
necting a DHW cylinder
Connection kit for DHW cylinder
A
B C
E
HR
SRL/KW
GA
SVL/WW
HV
OKFF
For gas combination boiler only
KW
Cold water b"
WW Hot water b"
For gas central heating boiler only
SRL Cylinder return c"
SVL Cylinder flow c"
*1
Obligatory in conjunction with DHW
cylinder positioned under the boiler,
recommended in other cases.
Please note:
Keep a clearance of 700 mm in front of
the Vitodens and the DHW cylinder for
servicing work.
No clearance is required for servicing
work on the left or right-hand side of the
Vitodens.
A Mounting aid
B Vitodens
C Entry point for electrical cables.
Leave cables projecting approx.
1200 mm from the wall.
D Wall-mounted DHW cylinder
(if installed)