Repressurising System - Baxi Platinum Combi 24 HE A User Operating Instructions Manual

Platinum combi he a series gas fired wall mounted condensing combination boiler
Table of Contents

Advertisement

Fig. 1
Fig. 2
Filling Loop
Connections
6
© Baxi Heating UK Ltd 2009
2
1
3
0
4
bar
Normal Pressure
2
1
3
0
4
bar
Requires
Repressurising
Fig. 3

3.0 Repressurising System

3.1
Central Heating System Pressure
1. The normal operating water pressure is between 1
and 2.5 bar (Fig. 1). If the pressure exceeds 3 bar the
safety pressure valve will operate and a fault is indicated.
Contact your installer.
2. It may be necessary to repressurise the system
occasionally (Fig. 2). A filling device (the filling loop) will
be fitted on the system. This will be on the boiler itself,
or on pipework near to the boiler.
3. If you are unsure of its position, or cannot identify it,
consult the installer who fitted the boiler.
4. The filling loop consists of two taps and a separate
copper pipe with connection fittings.
5. Only when repressurising should the copper pipe be
connected between the two taps. Ensure that the nuts
on the pipe ends are tightened onto the taps.
6. Fully open one of the taps first, and then while
watching the pressure gauge, carefully open the second
tap.
7. When the needle on the gauge is indicating 1 or more
turn both taps off.
8. Disconnect the copper pipe from the taps (a small
amount of water may be present) and remove it. Keep
the pipe in a safe place for future use.