MAINTENANCE INSTRUCTIONS for
APRILAIRE HUMIDIFIER MODELS 350-360
WARNING! 120 volts may cause serious injury from electrical shock.
Disconnect power and shut off water supply before servicing.
8
6
7
1. Note Humidistat setting and turn dial to the "off" position.
2. Disconnect electrical power and turn off water supply.
3. Remove screws of the inlet grille (1). The grille can now be removed from the metal
housing (8).
4. Lift the complete plastic framed evaporative section out of the humidifier housing.
5. To remove the distribution tray (2) from evaporative assembly (9), push down on tray
and pull out on white plastic frame (Scale Control Insert) (3). To clean the "V"
openings of the tray, it will be necessary to gently pry the distribution tray cover (4)
from the tray. Follow instructions below depending upon the type of distribution tray
in your humidifier.
For trays with a synthetic fabric liner: Lightly scrape out or brush off any mineral
deposits, being careful not to stretch or loosen the synthetic fabric liner. Soaking the
tray in vinegar or a lime-removing agent is helpful when trying to remove stubborn
mineral deposits.
For trays with granular coating: Do not scrape off the granular coating, but lightly
scrape out any mineral deposits and clean the "V" notches. This textured surface
helps ensure even water flow for maximum performance. See page 3 if removed.
6. Remove Water Panel evaporator (5) from the Scale Control Insert (3). Scrape the
Insert with a putty knife or similar tool and flush clean with water. Install new Water
Panel evaporator (Stock No. 35). Snap plastic cover into tray and tray into Scale
Control Insert.
7. Inspect the plastic feed tube by gently flexing it and looking for cracks or signs of
wear. Replace tube if it is cracked, brittle or has been damaged.
8. Remove the drain hose from the bottom of the unit and flex it to loosen the internal
calcium deposits. Then flush it with water under pressure and slip it back onto the
black drain fitting (6). Make sure the drain hose has a constant downward slope and
is not flattened or blocked.
9. Re-install complete plastic framed evaporative section and intake grille.
10. Reconnect electrical power.
11. Turn on water supply and check unit operation.
1
- 12 -
4
2
5
3
1. Inlet Grille
2. Distribution Tray
3. Scale Control Insert
4. Distribution Tray Cover
5. Water Panel
6. Drain Spud
7. Power Cord
8. Metal Housing
9. Evaporative Assembly
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

112220224350360440 ... Show all

Table of Contents