Download Print this page
York YP9C Technical Manual

York YP9C Technical Manual

Gas-fired residential multi-position gas furnace
Hide thumbs Also See for YP9C:

Advertisement

TECHNICAL GUIDE
UP TO 98%
MODULATING (ECM MOTOR)
GAS-FIRED RESIDENTIAL
MULTI-POSITION GAS FURNACES
MODELS: YP9C
NATURAL GAS
60 - 120 MBH INPUT
EFFICIENCY
RATING
CERTIFIED
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional efficiency rating information can
be found at www.gamanet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
ISO 9001
Certified Quality
Management System

DESCRIPTION

These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV listed and may be vented either
through side wall or roof applications using approved plastic
combustion air and venr piping.
WARRANTY
Lifetime limited warranty on both heat exchangers to the origi-
nal purchaser; a 20-year limited warranty from original installa-
tion date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial applica-
tions.
5-year limited parts warranty.

FEATURES

Modulating heating operation includes:
- Modulating gas valve, inducer and circulating blower
- Modulating operation from 100% to 35% input in 100%
increments with nearly constant temperature rise.
Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
ECM variable speed drive for cooling SEER enhancement,
improved comfort with optional airflow delay profiles, and
continuous fan options for IAQ performance.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit amp requirement for easy replacement application.
All models are convertable to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
100% shut off main gas valve for extra safety.
24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger with
stainless steel tube/aluminum fin secondary heat exchanger
for outstanding efficiency.
Solid removable bottom panel allows easy conversion.
Airflow leakage less than 1% of nominal airflow for
ductblaster conditions.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation, burner, and blower operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and
removal of blower.
External air filters used for maximum flexibility in meeting
customers IAQ needs.
Insulated blower compartment for thermal and acoustic
performance.
1/4 turn knobs provided for easy independent door removal.
Internal condensate trap design (patent pending) provides
condensate management options, easy visual operation
check, and is self priming to prevent nuisance problems.
410821-YTG-B-1008

Advertisement

loading

Summary of Contents for York YP9C

  • Page 1 • External air filters used for maximum flexibility in meeting Visit us on the web at www.york.com for the most customers IAQ needs. up-to-date technical information. • Insulated blower compartment for thermal and acoustic performance.
  • Page 2 410821-YTG-B-1008 RIGHT SIDE LEFT SIDE FRONT Combustion Air Inlet Combustion Air Inlet Condensate Drain Gas Pipe Gas Pipe Condensate Drain (Downflow) Entry Entry (Downflow) 2” Vent Electrical Electrical Connection Entry 2” Vent Entry Outlet Connection Condensate Outlet 33” Drain Condensate 23”...
  • Page 3 410821-YTG-B-1008 FILTER PERFORMANCE SIDEWALL VENT TERMINATION KIT - S1-1HT0901 (3") The airflow capacity data published in the “Blower Perfor- S1-1HT0902 (2") mance” table represents blower performance WITHOUT filters. All applications of these furnaces require the use of field For use on sidewall, two-pipe installations only. Provide a more installed air filters.
  • Page 4 Subject to change without notice. Printed in U.S.A. 410821-YTG-B-1008 Copyright © 2008 by Johnson Controls, Inc. All rights reserved. Supersedes: 410821-YTG-A-0708 Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069...