Download Print this page
York YP9C*C Technical Manual

York YP9C*C Technical Manual

Up to 98% modulating (ecm motor) gas-fired residential multi-position gas furnaces
Hide thumbs Also See for YP9C*C:

Advertisement

TECHNICAL GUIDE
UP TO 98%
MODULATING (ECM MOTOR)
GAS-FIRED RESIDENTIAL
MULTI-POSITION GAS FURNACES
MODELS: YP9C*C
NATURAL GAS
60 - 120 MBH INPUT
EFFICIENCY
RATING
CERTIFIED
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
Lifetime limited warranty on both heat exchangers to the original pur-
chaser; a 20-year limited warranty from original installation date to
subsequent purchaser.
10-year warranty on the heat exchanger in commercial applications.
Standard 5-year limited Parts warranty.
Extended 10-year limited parts warranty when product is regis-
tered online within 90 days of purchase for replacement or clos-
ing for new home construction.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV listed and may be vented either
through side wall or roof applications using approved plastic
combustion air and vent piping.
FEATURES
Modulating heating operation includes:
- Modulating gas valve, inducer and circulating blower
- Modulating operation from 100% to 35% input in 100
increments with nearly constant temperature rise.
Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
ECM variable speed drive for cooling SEER enhancement,
improved comfort with optional airflow delay profiles, and
continuous fan options for IAQ performance.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit amp requirement for easy replacement application.
All models are convertable to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
100% shut off main gas valve for extra safety.
24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
Airflow leakage less than 1% of nominal airflow for
ductblaster conditions.
Solid removable bottom panel allows easy conversion.
Hi-tech tubular aluminized steel primary heat exchanger with
stainless steel tube/aluminum fin secondary heat exchanger
for outstanding efficiency.
When paired with a
No knockouts to deal with, making installation easier.
York heat pump
Movable duct connector flanges for application flexibility.
Quiet inducer operation, burner, and blower operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and
removal of blower.
External air filters used for maximum flexibility in meeting
customers IAQ needs.
Insulated blower compartment for thermal and acoustic
performance.
1/4 turn knobs provided for easy independent door removal.
Internal condensate trap design (patent pending) provides
condensate management options, easy visual operation
check, and is self priming to prevent nuisance problems.
These models may be connected as part of a communicating
control system using a 4-wire connection bus.
The York YP9C modulating ECM furnace is part of a "Hybrid
Comfort System" when paired with a York Heat Pump.
538513- YTG-A-0809

Advertisement

loading

Summary of Contents for York YP9C*C

  • Page 1 These models may be connected as part of a communicating control system using a 4-wire connection bus. • The York YP9C modulating ECM furnace is part of a “Hybrid Comfort System” when paired with a York Heat Pump. 538513- YTG-A-0809...
  • Page 2 538513- YTG-A-0809 LEFT SIDE Combustion Air Inlet Condensate Drain (Downflow) 2” Vent Connection Outlet 28.5” 30.25” .56” 23.8” 3” Combustion Air Inlet .56” .56” 20” SUPPLY END Cabinet and Duct Dimensions Models YP9C060B12MP12C YP9C080B12MP12C YP9C080C16MP12C YP9C100C16MP12C YP9C100C20MP12C YP9C120D20MP12C Ratings & Physical / Electrical Data Input Max/Min Models...
  • Page 3 FILTER PERFORMANCE The airflow capacity data published in the “Blower Perfor- mance” table represents blower performance WITHOUT filters. All applications of these furnaces require the use of field installed air filters. All filter media and mounting hardware or provisions must be field installed external to the furnace cabi- net.
  • Page 4 1170 1595 1035 1620 1050 1255 1435 1050 1160 1035 Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069 Jumper Settings COOL Jumper ADJ Jumper Jumper Settings COOL Jumper ADJ Jumper Jumper Settings COOL Jumper ADJ Jumper 538513- YTG-A-0809...

This manual is also suitable for:

Yp9c060b12mp12cYp9c080b12mp12cYp9c080c16mp12cYp9c100c16mp12cYp9c100c20mp12cYp9c120d20mp12c