Connecting Water Supply - Cornelius QUEST ELITE 2000 Installation Manual

Hide thumbs Also See for QUEST ELITE 2000:
Table of Contents

Advertisement

Quest Elite 2000 Installation Manual

CONNECTING WATER SUPPLY

Publication Number: 620048922INS
The Quest Elite series Juice Dispenser is designed to dispense juice at a high
flow rate. It is very important that the incoming water line be dedicated for use by
the dispenser only and does not have other machines connected which could
cause a water surge, (i.e., a dishwasher, coffee maker, etc.).
IMPORTANT:
The water supply should be consistent with proper
water quality standards (neutral pH of 7.0 to 8.0), and
should not be connected to a water softener. It is the
installer's responsibility to ensure that all water
connections to the dispenser are sized, installed with
adequate backflow protection and maintained to
comply with Federal, State, and Local Laws.
1. Secure the 3/8" (0.95 cm) swivel nut on the flexible supply tubing to the
water inlet located at the rear of the dispenser. Make sure that the flared
gasket is used (flared gasket P/N 311304000 is included with the installation
kit).
Water Inlet
with Supply Tubing
Connected
Figure 7. Water Supply Connection on Rear of Unit
2. When securing flare nut, use a backup wrench on the male side of the inlet
fitting (unit side) to prevent twisting of the copper tube inside the unit and/or
possible damage to the water strainer/solenoid. Water shut off outside the
unit is recommended.
- 12 -
© 2010-2012, IMI Cornelius Inc.

Advertisement