Maintenance; Cleaning The Filter; Resetting The Filter Counter - Sanyo PLC-WXU700 Service Manual

Hide thumbs Also See for PLC-WXU700:
Table of Contents

Advertisement

Maintenance

Cleaning the Filter

Filter prevents dust from accumulating on the optical elements inside the projector. Should the filters become
clogged with dust particles, it will reduce cooling fans' effectiveness and may result in internal heat buildup
and adversely affect the life of the projector. If a Filter warning icon appears on the screen, clean the filters
immediately. Clean the filters by following the steps below.
1
Turn off the projector, and unplug the AC power cord
from the AC outlet.
2
Turn the projector over and remove the filters by
pulling the latches upward.
3
Gently clean the filters by using a brush or rinse it
softly.
4
When rinsing the filters, dry they well. Replace the
filters properly. Make sure that the filters are fully
inserted to the projector.
CAUtION
Do not operate the projector with the filters
removed. Dust may accumulate on the optical
elements degrading picture quality.
Do not put anything into the air vents. Doing so
may result in malfunction of the projector.
reCOMMeNdAtION
We recommend avoiding dusty/smoky environments
when you operate the projector. Usage in these
environments may cause poor image quality.
When using the projector under dusty or smoky
conditions, dust may accumulate on a lens, LCD panels, or
optical elements inside the projector degrading the quality
of a projected image. When the symptoms above are
noticed, contact your authorized dealer or service station
for proper cleaning.

Resetting the Filter Counter

Be sure to reset the Filter counter after cleaning or replacing
the filters.
1
Press the MENU button to display the On-Screen
Menu. Use the Point buttons to select Setting and
then press the Point
2
Use the Point buttons to select Filter counter and
then press the SELECT button. Use the Point buttons
to select Filter counter reset and then press the
SELECT button. Filter counter reset? appears. Select
Yes to continue.
3
Another confirmation dialog box appears, select Yes to
reset the Filter counter.
or the
button.
SELECT
Filters
Pull up and remove.
Filter counter
-7-
H
Filter counter reset?
appears.
Select Yes, then
another confirmation
box appears.
Select Yes again
to reset the Filter
counter.

Advertisement

Table of Contents
loading