Sanyo PLC-WXU700 Service Manual page 46

Hide thumbs Also See for PLC-WXU700:
Table of Contents

Advertisement

Electrical Adjustments
Group/
Item Name
Item
1 Frequency Step
 Frequency Threshold
 Fine Phase
4 BLKDET
5 PHASEMSK
Group
Paneltype * Panel type Check
290
0 GammaL/R-View
1 GammaL/R-Change
Group
Closed capture
300
0 Caption Mode
1 Color Mode
Group
Composite (NtSC) Composite / S-Video
500
0
1 Disp Dots
 H Back Porch
 V Back Porch
4 Disp Line
Group
Composite (PAL) Composite / S-Video
501
0
1 Disp Dots
 H Back Porch
 V Back Porch
4 Disp Line
Group
Composite (SeCAM) Composite / S-Video
502
0
1 Disp Dots
 H Back Porch
 V Back Porch
4 Disp Line
Group
SCArt(480i)
510
0 TRotal DOts
1 Disp Dots
 H Back Porch
 V Back Porch
4 Disp Line
5 Clamp
6 Clamp Width
5 (USB)Clamp
6 (USB)Clamp Width
Group
SCArt (575i)
511
0
1 Disp Dots
 H Back Porch
 V Back Porch
4 Disp Line
5 Clamp
6 Clamp Width
5 (USB)Clamp
6 (USB)Clamp Width
Group
YCbCr (480i)
520
0 Total Dots
Function
Frequency Steps of TotalDot
Total Dot Freqency Threshold
Do Phase Adj after Total Dot Adj.
Black Level Detection Area
Phase Detection Filter
Current Setting Check
Setting of Gamma
Capture Mode:
OFF/CC1/CC/CC/CC4
Color Mode
Initial
1
5
1
1
0
0
10
0
0
674
4
18
454
660
4
18
54
66

18
54
858
664
117
41
458
0
0
0
0
648
144
64
54
0
0
0
0
858
-46-
range
Note
0-
0 - 10
0 [] <--- -----> 10[Not matched]
0: Executes Fine Phase, 1: Not
0 - 1
Execute
0 - 
0: Effective All Bit,
1: Disable Lower 1 bit
0 - 
: Disable Lower  bit, : Disable
Lower  bit
0: Gamma for L-Turn
0-0
0: Gamma for R-Turn * Read only
Sets L-Turn Gamma if the Value is
set to 0.
0-0
Sets R-Turn Gamma if the Value is
set to 0.
0-5
0-1
0 - 4095
0 - 4095
0 - 4095
0 - 4095
0 - 4095
0 - 4095
0 - 4095
0 - 4095
0 - 4095
0 - 4095
0 - 4095
0 - 4095
0 - 4095
0 - 4095
0 - 4095
0 - 4095
0 - 4095
0 - 55
0 - 55
0 - 4095
0 - 4095
0 - 4095
0 - 4095
0 - 4095
0 - 4095
0 - 55
0 - 55
0 - 4095
0 - 4095
0 - 4095

Advertisement

Table of Contents
loading

Table of Contents