MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under Lighting
Instructions, page 20.
2. Press control knob and light pilot with
match.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow steps 9
Lighting Instructions, page 20.
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: Hand-held remote control accessories
must be purchased separately (see Acces-
sories, page 34). Follow instructions included
with the remote control.
NOTICE: you must light the pilot
before using the hand-held re-
mote control unit. See Lighting
Instructions on page 19.
Check pilot flame pattern and burner flame
patterns often.
PILOT FLAME PATTERN
Figure 28 shows a correct pilot flame pattern.
Figure 29, shows an incorrect pilot flame pat-
tern. The incorrect pilot flame is not properly
heating the thermocouple. When the ther-
mocouple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown
in Figure 29.
• turn heater off (see To Turn Off Gas to Ap-
pliance, page 20)
• see Troubleshooting, page 23.
Note: The pilot flame on natural gas units will
have a slight curve, but the flame should be
blue and have no yellow or orange color.
111161-01L
OPERATION
Continued

INSPEcTING BURNERS

www.fmiproducts.com
After lighting, let pilot flame burn for about
one minute. Turn control knob to ON position.
Adjust flame adjustment knob anywhere be-
tween HI and LO. Slide the selector switch to
the REMOTE position (see Figure 27).
Note: The burner may light if hand-held re-
mote was on when selector switch was last
turned off. You can now turn the burner on and
off with the hand-held remote control unit.
IMPORTANT: Do not leave the selector switch
in the REMOTE or ON position when the pilot
is not lit. This will drain the battery.
Flame Adjustment
Knob
Selector Switch in Remote Position
Figure 32 - Setting the Selector Switch,
Control Knob and Flame Adjustment
Knob for Remote Operation
Pilot Burner
Propane/LP
Gas
Thermocouple
Figure 28 - Correct Pilot Flame Pattern
Pilot Burner
Propane/LP
Gas
Thermocouple
Figure 29 - Incorrect Pilot Flame Pattern
Control
Knob
ON
OFF
REMOTE
Natural Gas
Pilot
Natural Gas
Burner
21