To Replace Regulator - Craftsman 919.168700 Owner's Manual

Permanently lubricated single stage portable air compressor
Hide thumbs Also See for 919.168700:
Table of Contents

Advertisement

Available languages

Available languages

To Replace Regulator

1.
Release all air pressure from air
tank. See "To Drain Tank" in the
"Maintenance" section.
2.
Set the On/Auto/Off lever to "Off"
and unplug unit.
3.
Remove the outlet pressure
gauge and quick connect (if
equipped) from the regulator.
4.
Remove the regulator.
5.
Apply pipe sealant tape to the
nipple.
A09711
6.
Assemble the regulator and
orient as shown.
NOTE: Arrow indicates flow of air.
Make sure it is pointing in the
direction of air flow.
7.
Reapply pipe sealant to outlet
pressure gauge and quick
connect.
8.
Reassemble outlet pressure
gauge and quick connect. Orient
outlet pressure gauge to read
correctly. Tighten quick connect
with wrench.
18- ENG