Service And Adjustments; To Repalce Or Clean Check Valve; Motor; To Replace Regulator - Craftsman 919.167210 Operator's Manual

Permanently lubricated single stage portable air compressor
Table of Contents

Advertisement

Available languages

Available languages

Unit cycles automatically when power is on. When doing Maintenance, you may be exposed
to voltage sources, compressed air or moving parts. Personal injuries can occur. Before per-
forming any Maintenance or repair, unplug the compressor and bleed off all air pressure.
ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY
TRAINED SERVICE TECHNICIAN.
Before servicing:
G
Unplug or disconnect electrical supply to the
air compressor.
G
Bleed tank of pressure.
G
Allow the air compressor to cool.
To Replace or Clean Check Valve
1. Release all air pressure from air tank. See "To
Drain Tank" in the Maintenance section.
2. Unplug outfit.
3. Remove the regulator ring and remove the con-
sole cover.
Regulator
Ring
4. Remove shrouds.
5. Using an adjustable wrench loosen outlet tube nut
at air tank and pump. Carefully move outlet tube
up away from check valve.
Outlet Tube
Pressure
Relief Tube
Nut
6. Using an adjustable wrench loosen pressure relief
tube nut at air tank and pressure switch. Carefully
move pressure relief tube away from check valve.
7. Unscrew the check valve (turn counterclockwise)
using a 7/8" open end wrench. Note the orienta-
tion for reassembly.
D23377

SERVICE AND ADJUSTMENTS

Cover
Nut
Check
Valve
8. Using a screwdriver, carefully push the valve disc
up and down. NOTE: The valve disc should move
freely up and down on a spring which holds the
valve disc in the closed position, if not the check
valve needs to be cleaned or replaced.
In open position
nothing is visible.
9. Clean or replace the check valve. A solvent, such
as paint or varnish remover can be used to clean
the check valve.
10. Apply sealant to the check valve threads. Reinstall
the check valve (turn clockwise).
11. Replace the pressure release tube. Tighten nuts.
12. Replace the outlet tube and tighten nuts.
13. Replace shrouds and console.
14. Perform the Break-in Procedure. See "Break-in
Procedure" in the Operation section.

To Replace Regulator

1. Release all air pressure from air tank. See "To
Drain Tank" in the Maintenance section.
2. Unplug outfit.
3. Remove the regulator ring and remove the con-
sole cover.
Regulator
Ring
14 - ENG
Screwdriver
In closed position
disc is visible.