BLOWER DATA
SLP98UH070XV36B BLOWER PERFORMANCE (less filter)
SINGLE SIDE RETURN AIR WITH OPTIONAL RETURN AIR BASE
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5% ) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
The effect of static pressure is included in air volumes shown.
The following control configurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single stage thermostat:
- 35%, 70%, 100% input (three-stage) with time delays in-between
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages
Cool Mode Available (Cooling Blower Performance table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately 28%, 38%, 70% and 100% (DIP switch selectable) of the same second-stage COOL speed position
minimum 300 cfm.
Lennox Harmony III™ Zoning System Applications - Minimum blower speed is 250 cfm.
SLP98UH070XV36B BLOWER MOTOR WATTS - COOLING
Blower Speed
Options
0
0.1
Increase (+10%) Cool CFM
Low
18
32
Medium-Low
34
52
Medium-High
63
82
High
88
107 131 148 175 192 217 235 253 255 281 312 346 382 402 430 465 489 506 533
Default Cool CFM
Low
12
25
Medium-Low
25
40
Medium-High
41
61
High
63
86
Decrease (-10%) Cool CFM
Low
9
20
Medium-Low
16
32
Medium-High
28
43
High
46
61
SLP98UHV / Page 22
35%
471
435
399
369
339
First Stage Cool Speed - cfm
Low
Medium-
Low
595
715
520
655
490
595
Motor Watts @ Various External Static Pressures - in. wg.
First Stage
0.2
0.3
0.4
0.5
0.6
46
61
76
89
104 115 133
69
86
104 126 141 160 174 109 131 150 179 204 219 239 268 283 313 335
98
115 138 153 173 187 209 177 197 227 246 273 311 328 354 383 402 408
37
55
66
82
94
55
74
89
109 120 136 150
75
98
115 135 151 173 189 129 150 177 198 227 247 272 301 324 332 369
99
122 139 159 180 204 216 209 227 254 282 298 324 341 364 395 413 428
35
48
59
75
86
45
62
75
90
103 119 138
63
77
98
115 132 145 162
86
100 121 136 153 172 193 142 163 187 216 236 261 279 301 325 356 375
Heating Input Range and Blower Volume - CFM
40%
50%
60%
519
614
709
480
570
660
441
526
611
408
486
564
375
446
517
Blower Speed Selections
Medium
High
Low
High
(Default)
815
950
855
755
840
790
670
745
720
0.7
0.8
0
0.1
0.2
64
83
95
105 121
43
61
76
76
96
112 138 162 186 207 232 243 262 281
94
110
29
43
63
56
71
101 112 131 158 168 184 207 235 245
88
107 129 154 183 204 214 245 263 281 308
70%
80%
90%
805
900
996
751
841
931
696
781
866
643
721
799
589
660
732
Second Stage Cool Speed - cfm
Medium-
Medium
Low
High
1045
1205
945
1090
845
985
Second Stage
0.3
0.4
0.5
0.6
0.7
120 141 159 175 203 208 234 246
99
121 133 162 169 189 211 224
84
99
113 131 144 164 185 197
100%
1091
1021
951
877
803
High
(Default)
1350
1255
1130
0.8
0.9
1.0