Selection Of Regenerative Brake (Pr. 30, Pr. 70) (75K Or More) - Mitsubishi Electric FR-B-750 to 75K Instruction Manual

Fr-b-750 to 75k (200v class), fr-b-750 to 110k (400v class)
Table of Contents

Advertisement

Motor brake and stop operation

4.10.2 Selection of regenerative brake (Pr. 30, Pr. 70) (75K or more)

Setting can be made only for FR-B series.
When making frequent starts/stops, use the brake unit (FR-BU, MT-BU5) to increase the regenerative brake
duty.
Use a power regeneration converter (MT-RC) for continuous operation in regenerative status.
Use a high power factor converter (MT-HC) to reduce harmonics, improve the power factor, or continuously use
the regenerative mode.
CAUTION
The regenerative brake option (brake unit) can be used with the 75K or more of FR-B series. Cannot be used with the 55K or less.
Parameter
Name
Number
Regenerative function
30
selection
Special regenerative
70
brake duty
Regeneration Unit
Not used
Power regeneration converter (MT-RC) R/L1, S/L2, T/L3
Brake unit (MT-BU5)
High power factor converter (FR-HC)
(1) When the built-in brake resistor, the brake unit (FR-BU) is used
⋅ Set "0 (initial value)" in Pr. 30. The Pr. 70 setting is made invalid.
At this time, the regenerative brake duty is as follows. (The built-in brake resistor is provided for the 7.5K or less.)
⋅ FR-B-750 to 3700(200V) ........................ 3%
⋅ FR-B-5.5K, 7.5K(200V) .......................... 2%
⋅ FR-B-750 to 7.5K(400V) ........................ 2%
⋅ FR-B-75K or more (200V/400V)............. 0% (without built-in brake resistor)
(2) When using a brake unit (MT-BU5) and power regeneration converter (MT-RC) (FR-B-75K or
more)
⋅ Set "1" in Pr. 30.
⋅ Set "10%" in Pr. 70 when using a brake unit (MT-BU5).
⋅ Set "0%" in Pr. 70 when using a power regeneration converter (MT-RC).
102
Setting Range
Initial
Value
FR-B
FR-B3
0
0
1
2
0%
0 to 10%*
Power Supply to the
Inverter
R/L1, S/L2, T/L3
R/L1, S/L2, T/L3
P/+, N/-
Description
Regeneration unit
Built-in brake resistor, without
regenerative function, brake unit
(FR-BU type)
Brake unit (MT-BU5), power
regeneration converter (MT-RC)
Supports capacities of the FR-B-
75K or more.
High power factor converter (MT-
HC)
Supports capacities of the FR-B-
75K or more.
Set the %ED of the built-in brake transistor operation.
* Supports capacities of the FR-B-75K or more.
Pr. 30
Pr. 70
Setting
Setting
0
(initial value)
0%
1
(initial value)
1
10%
2
B
B
Terminal for power
supply to the inverter
R, S, T
R, S, T
P, N

Hide quick links: