Parameter List
Func-
Parame-
tion
ter
PID control automatic switchover
127
frequency
128
PID action selection
129
PID proportional band
130
PID integral time
131
PID upper limit
132
PID lower limit
133
PID action set point
134
PID differential time
Backlash acceleration stopping
140
frequency
141
Backlash acceleration stopping time
Backlash deceleration stopping
142
frequency
143
Backlash deceleration stopping time
144
Speed setting switchover
145
PU display language selection
148
Stall prevention level at 0V input
149
Stall prevention level at 10V input
150
Output current detection level
Output current detection signal delay
151
time
152
Zero current detection level
153
Zero current detection time
Voltage reduction selection during stall
154
prevention operation
RT signal function validity condition
155
selection
156
Stall prevention operation selection
157
OL signal output timer
158
AM terminal function selection
160
User group read selection
Frequency setting/key lock operation
161
selection
Automatic restart after instantaneous
162
power failure selection
163
First cushion time for restart
164
First cushion voltage for restart
Stall prevention operation level for
165
restart
Output current detection signal
166
retention time
Output current detection operation
167
selection
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
171
Operation hour meter clear
58
Name
FR-B
0 to 120Hz/
0 to 60Hz,
9999
10, 11, 20, 21, 50, 51, 60,
61
0.1 to 1000%, 9999
0.1 to 3600s, 9999
0 to 100%, 9999
0 to 100%, 9999
0 to 100%, 9999
0.01 to 10.00s, 9999
0 to 120Hz/
0 to 60Hz
0 to 360s
0 to 120Hz/
0 to 60Hz
0 to 360s
0, 2, 4, 6, 8, 10, 102,
104, 106, 108, 110
0 to 7
0 to 220%
0 to 220%
0 to 220%
0 to 10s
0 to 220%
0 to 1s
0, 1
0, 10
0 to 31, 100, 101
0 to 25s, 9999
1 to 3, 5, 6,
8 to 14, 17,
18, 21, 24,
50, 52, 53
0, 1, 9999
0, 1, 10, 11
0, 1, 2, 10, 11, 12
0 to 20s
0 to 100%
0 to 220%
0 to 10s, 9999
0, 1
0, 10, 9999
0, 9999
Setting Range
Minimum
Setting
FR-B3
Increments
0 to
0.01Hz
120Hz,
9999
*1
1
0.1%
0.1s
0.1%
0.1%
0.01%
0.01s
0 to 120Hz
0.01Hz
*1
0.1s
0.01Hz
0 to 120Hz
*1
0.1s
1
1
0.1%
0.1%
0.1%
0.1s
0.1%
0.01s
1
1
1
0.1s
1 to 3, 5 to
14, 17, 18,
1
21, 24, 34,
50, 52, 53
1
1
1
0.1s
0.1%
0.1%
0.1s
1
1
1
Initial Value
Refer
Customer
to
Setting
FR-B
FR-B3
Page
9999
228
10
228
100%
228
1s
228
9999
228
9999
228
9999
228
9999
228
1Hz
91
0.5s
91
1Hz
91
0.5s
91
4
135
0
253
150%
74
200%
74
150%
132
0s
132
5%
132
0.5s
132
1
74
0
122
0
74
0s
74
1
137
0
180
0
253
0
148
0s
148
0%
148
150%
148
0.1s
132
0
132
9999
137
9999
137