7.5

Adjustment Mode

NOTE:
See section 7.2.1 for a list of the equipment and setup procedures required to perform the following adjustment and
calibration procedures.
The following procedures MUST be performed after replacement or repair of one or both of the PCBs in the
handheld unit. Failure to do so may result in incorrect operation of the telephone.
The following adjustments MUST be made on BOARD PAIRS.
There are four distinct calibration procedures to adjust RF performance. These procedures are:
1.
Ramping gain (Section 7.5.1)
2.
RSSI (Section 7.5.2)
3.
I and Q values (Section 7.5.3)
The adjustment data selected during calibration is stored in the telephone EEPROM.
NOTE:
As G600 has two battery types available, Lithium Ion and Nickel Metal Hydride, all calibration procedures must be
carried out for each battery type.
Figure 10: Test software screen
7.5.1 Ramping Gain
The carrier power must be measured and calibrated for each power level at channel 62.
Target
Power Level
PL5
PL6
PL7
PL8
PL9
PL10
PL11
PL12
PL13
PL14
PL15
PL16
PL17
MCUK980101C8
Service Manual
http://cxema.ru
Peak Power
Tolerance
(dBm)
(dB)
33
±2
31
±3
29
±3
27
±3
25
±3
23
±3
21
±3
19
±3
17
±3
15
±3
13
±3
11
±5
9
±5
Initial Calibration Value
4.8V
7.2V
192
170
157
150
134
130
118
116
106
104
96
94
87
85
117
115
108
106
101
99
95
93
90
87
85
83
Section 7
7 - 9
TEST AND MEASUREMENT
600-0721
Change per dB
4.8V
7.2V
14.29
40.00
12.50
20.00
5.56
10.00
7.69
7.14
5.88
6.25
5.00
5.26
4.00
4.25
5.00
5.00
4.00
4.35
3.45
3.57
2.94
3.03
2.56
2.63
2.17
2.22
Issue 1
Revision 0