10. Technical specifications

Model no.
Measurement method
Measurement range
Accuracy
Measurement inaccuracy
Memory
Dimensions
Weight
Cuff size
Permissible operating temperature +10 °C to + 40 °C, 30 – 85 % relative humidity
Permissible storage temperature
Power supply
Battery life
Accessories
Protection class
Signs and symbols
Technical information is subject to change without notification to allow for updates.
• This unit is in line with the European Standard EN 60601-1-2 and is subject to particular precautions
with regard to electromagnetic compatibility. Please note that portable and mobile HF communication
systems may interfere with this unit. More details can be requested from the stated Customer Service
address or found at the end of the instructions for use.
• This unit is in line with the EU Medical Devices Directive 93/42/EC, the "Medizinproduktegesetz" (German
Medical Devices Act) and European Standard EN1060-1 (non-invasive sphygmomanometers, Part 1:
General requirements) and EN1060-3 (non-invasive sphygmomanometers, Part 3: Supplementary require-
ments for electro-mechanical blood pressure measuring systems).
Power supply unit
Model No.
Input
Output
Supplier
Protection
SBM 52
Oscillometric, non-invasive blood pressure measurement on the upper arm
pressure 0 – 300 mmHg, systolic 50 – 250 mmHg, diastolic 30 – 200 mmHg,
pulse 30 –180 beats per minute
systolic ± 3 mmHg / diastolic ± 3 mmHg / pulse ± 5 % of the value shown
Max. permissible standard deviation according to clinical testing:
systolic 8 mmHg / diastolic 8 mmHg
4 x 30 memory spaces
(L) 134 x (W) 102 x (H) 53 mm
Approximately 287 g
22 to 36 cm
- 5 °C to + 50 °C, 10 – 85 % relative humidity
4 x 1.5 V AA batteries (alkaline type LR6)
For approx. 250 measurements, depending on levels of blood pressure
and pump pressure
Storage pouch, instructions, 4 x 1.5 V AA batteries
Internal supply, IPX0, no AP or APG, continuous operation
Application part type B
Caution!
Read the instructions for use!
Manufacturer
FW7333SM/06
100 – 240 V, 50 – 60 Hz
6 V DC, 1150 mA, only in connection with Sanitas blood pressure monitor
Friwo Gerätebau GmbH
This device is double isolated and protected against short circuit and
overload by a primary thermal fuse.
The green LED lights under normal conditions.
Make sure to take the batteries out of the compartment before using the
adapter.
double isolated / equipment class 2