Gas Leak Test; Test Operation; Selector Switch; Auto Restart Setting - Toshiba RAS-10(7)~16(7)SKV Series Installation Manual

Air conditioner (split type)
Table of Contents

Advertisement

Stripping length of the connecting cable
10(7)SAV(R) Series
Terminal
block
45
Connecting
Power
cable
cord
13(7)~16(7)SAV(R) Series
Terminal
block
30
Connecting
Power
cable
cord
Model
Power source
Maximum running current
Plug socket & fuse rating
Power cord

Gas Leak Test

Valve cover
Electric parts
cover
Check places for
the outdoor unit.
Setting of Remote Control

Selector Switch

When two indoor units are installed in the separated rooms, it is not
necessary to change the selector switches.
Remote control selector switch
• When two indoor units are installed in the same room or adjacent two
rooms, if operating a unit, two units may receive the remote control
signal simultaneously and operate. In this case, the operation can be
preserved by setting either one indoor unit or remote control to B set-
ting. (Both are set to A setting in factory shipment.)
• The remote control signal is not received when the settings of indoor
unit and remote control are different.
• There is no relation between A setting/B setting and A room/B room
when connecting the piping and cables.
Remote Control A-B Selection
To separate using of remote control for each indoor unit in case of 2 air
conditioner are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold [CHK] button on the Remote Control by the tip of the pencil.
"00" will be shown on the display.
1110251155-EN.indd 7
1 2 3
L N
60
50
40
Earth line
Earth line
Connecting cable
Power cord
1 2 3
L N
40
40
30
Earth line
Earth line
Connecting cable
Power cord
10(7)SKV(R)
13(7)~16(7)SKV(R)
50Hz, 220 – 240 V Single phase
8A
11A
25A
H07RN-F or 245 IEC66 (1.5 mm
2
or more)
OTHERS
Check places for
the indoor unit.
• Check the Á are nut connec-
tions for the gas leak with a
gas leak detector or soap
water.
CAUTION
• Wrong wiring connection may cause some electrical parts burn out.
• Be sure to comply with local cords on running the wire from indoor unit
to outdoor unit (size of wire and wiring method, etc.).
• Every wire must be connected À rmly.
• This installation fuse (25A) must be used for the power supply line of
this air conditioner.
• If incorrect or incomplete wiring is carried out, it will cause an ignition or
smoke.
• Prepare the power supply for exclusive use with the air conditioner.
• This product can be connected to the mains.
Connection to À xed wiring: A switch which disconnects all poles and
has a contact separation of at least 3 mm must be incorporated in the
À xed wiring.
NOTE
: Connecting cable
• Wire type : More than H07RN-F or 245 IEC66
4. Press [MODE] during pushing [CHK]. "B" will show on the display and "00"
will disappear and the air conditioner will turn OFF. The Remote Control B
is memorized.
Note : 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A have not "A" display.
3. Default setting of Remote Control from factory is A.
10~16SKV(R) Series
"B" Display
"00" Display
PRESET
FAN

Test Operation

To switch the TEST RUN (COOL) mode,
press RESET button for 10 seconds. (The
beeper will make a short beep.)
RESET button

Auto Restart Setting

This product is designed so that, after a power failure, it can restart automatically
in the same operating mode as before the power failure.
Information
The product was shipped with Auto Restart function in the off position.
Turn it on as required.

How to set the Auto Restart

• Press and hold the RESET button for about 3 seconds. After 3 seconds, the
electronic beeper makes three short beeps to tell you the Auto Restart has
been selected.
• To cancel the Auto Restart, follow the steps described in the section Auto
Restart Function of the owner's manual.
7
107~167 SKV Series
MODE
TEMP.
FAN
AUTO
AUTO
COOL
QUIET
B
B
DRY
HEAT
TEMP.
12/18/07 3:47:30 PM

Advertisement

Table of Contents
loading

Table of Contents