Rheem RPVS Series Installation, Operation & Maintenance Instructions Manual page 27

Split geothermal products residential indoor and outdoor split geothermal heat pumps
Table of Contents

Advertisement

Hot Water Generator Module Refrigeration Installation
Figure 13a: Outdoor Compressor Section HWG
Installation
Refr to
HWG
Refr from
HWG
Figure 13b: Remote HWG Module
Control
Board
HWG
Refr In
Circulator
Figure 13d: HWG Bypass Valve
Valve Open
(HWG Bypassed)
Figure 15: HWG Wiring
TO RELAY R1 IN COMPRESSOR SECTION
CONDENSER
CONDENSER
For Outdoor Compressor Section Only
Fully Insulated
Lines to the HWG
HWG
Water Out
HWG
Refr Out
High Voltage
HWG
Water In
Valve Closed
(HWG Activated)
Figure 14: HWG Refrigerant Line Sizing
Capacity
1/2" OD
Up to 16 ft.
2 Ton
[4.9m]
Up to 9 ft.
3 Ton
[2.7m]
Up to 5 ft.
4 Ton
[1.5m]
5 Ton
N/A
Figure 13c: HWG Service Valves
Refr
to HWG
Refr from
HWG
R e s i d e n t i a l S p l i t
R e v. : 1 3 M a r c h , 2 0 1 5
Line Set Size
5/8" OD
3/4" OD
Up to 30 ft.
N/A
[9.1m]
Up to 25 ft.
Up to 30 ft.
[7.6m]
[9.1m]
Up to 13 ft.
Up to 30 ft.
[4.0m]
[9.1m]
Up to 9 ft.
Up to 25 ft.
[2.7m]
[7.6m]
HWG
Bypass
Valve
HWG
Line Valves
27