3-2 Operating Instruction

3-2-1 Thermostat control

Off :
When the room temperature is lowered by the air conditioner, the gas within the thermostat
will contract and cause a break in the electric contact.
The compressor will then stop.
After the compressor stops, the room temperature will rise.
On :
As the room temperature increases to a selected level, the gas within the thermostat expands,
causing electric contact, which provides the source of electric power to the compressor.
The room temperature will fall, and the cycle will repeat.
Control Operation :
By turning the control knob clockwise(toward higher numbers), the temperatures will be cooler.
By turning the control knob counterclockwise(toward lower numbers), the temperature will be
warmer.
Level 1 : Cool air will be supplied above 30~35¡ .
Cool air will be ceased below 28~32.5¡ .
Level 10 : Cool air will be supplied above 17.4~20.4¡ .
Cool air will be ceased below 14.4~17.4¡ .