MAINTENANCE

To ensure continuing high performance and to minimize the
possibility of premature equipment failure, periodic maintenance
must be performed on this equipment. This
inspected at least once each year by a qualified service person. To
troubleshoot unit, refer to Table 12- -14, Troubleshooting Chart.
NOTE TO EQUIPMENT OWNER: Consult your local dealer
about the availability of a maintenance contract.
WARNING
!
PERSONAL
INJURY
HAZARD
Failure to follow this warning could result in personal
injury or death and unit component damage.
The ability to properly perform maintenance on this
equipment requires certain expertise, mechanical skills,
tools and equipment. If you do not possess these, do not
attempt to perform any maintenance on this equipment,
other than those procedures recommended in the Owner's
Manual.
WARNING
!
ELECTRICAL SHOCK HAZARD
Failure to follow these warnings could result in personal
injury or death:
1. Turn off electrical power to the unit and install lock out
tag before performing any maintenance or service on this
unit.
2. Use extreme caution when removing panels and parts.
3. Never place anything combustible either on or in contact
with the unit.
CAUTION
!
UNIT OPERATION HAZARD
Failure to follow this caution may result in improper
operation.
Errors made when reconnecting wires may cause improper
and dangerous operation. Label all wires prior to
disconnecting when servicing.
Table 10 – 574D- -- -A Wet Coil Pressure Drop (IN. W.C.)
STANDARD CFM (S.C.F.M)
900
1000
1100
0.053
0.063
---
0.053
0.063
0.072
0.055
0.060
0.090
---
0.045
0.050
---
---
---
---
---
---
0.1
0.2
0.3
1333
1289
1256
1612
1569
1527
2166
2085
2002
2298
2239
2180
unit should be
AND
UNIT
DAMAGE
1200
1300
1400
1500
---
---
---
---
0.081
0.105
---
---
0.100
0.110
0.140
---
0.060
0.065
0.075
0.080
0.041
0.063
0.085
0.100
---
---
---
0.060
EXTERNAL STATIC PRESSURE (IN. W.C.)
0.4
0.5
0.6
1214
1152
1118
1481
1451
1393
1919
1798
1709
2110
2044
1951
!
ENVIRONMENTAL HAZARD
Failure to follow this caution may result in environmental
pollution.
Remove and re- -cycle all components or materials (i.e. oil,
refrigerant, etc) before unit final disposal.
The minimum maintenance requirements for this equipment are as
follows:
1. Inspect air filter(s) each month. Clean or replace when
necessary.
2. Inspect indoor coil, drain pan, and condensate drain each
cooling season for cleanliness. Clean when necessary.
3. Inspect blower motor and wheel for cleanliness at the
beginning of each heating and cooling season. Clean when
necessary. For first heating and cooling season, inspect
blower wheel bi- -monthly to determine proper cleaning
frequency.
4. Check electrical connections for tightness and controls for
proper operation each heating and cooling season. Service
when necessary.
5. Ensure electric wires are not in contact with refrigerant
tubing or sharp metal edges.
6. Check and inspect heating section before each heating
season. Clean and adjust when necessary.
7. Check flue hood and remove any obstructions, if necessary.

Air Filter

IMPORTANT: Never operate the unit without a suitable air filter
in the return- -air duct system. Always replace the filter with the
same dimensional size and type as originally installed. See Table 1
for recommended filter sizes.
Inspect air filter(s) at least once each month and replace
(throwaway- -type) or clean (cleanable- -type) at least twice during
each cooling season and twice during the heating season, or
whenever the filter becomes clogged with dust and lint.

Indoor Blower and Motor

NOTE: All motors are pre- -lubricated. Do not attempt to lubricate
these motors.
For longer life, operating economy, and continuing efficiency,
clean accumulated dirt and grease from the blower wheel and
motor annually.
31
1600
1700
1800
---
---
---
---
---
---
---
---
---
0.090
0.094
0.110
0.104
0.110
0.120
0.065
0.072
0.077
0.7
0.8
0.9
1076
1035
997
1351
1317
1278
1582
1467
1270
1862
1777
1697
CAUTION
1900
2000
---
---
---
---
---
---
---
---
0.130
---
0.085
0.100
1.0
950
1242
988
1591

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Legacy 574dnwa24040aaLegacy 574dnwa24040naLegacy 574dnwa24060aaLegacy 574dnwa24060naLegacy 574dnwa30040aaLegacy 574dnwa30040na ... Show all

Table of Contents