Step
Parts to remove
Blower housing
7
Control box
8
Chock control lever and link
LINK PIVOT
CHOKE
CONTROL ROD
RETURN
SPRING
STEP 8
Remarks and procedures
Disconnect fuel pipe and remove blower
housing along with control box.
(1) Remove the choke knob.
(2) Remove the choke contol link.
WAVED
WASHER
M5 TAPPING
SCREW
CLAMP
CHOKE
KNOB
CHOKE
CONTROL
LINK
– 18 –
Fasteners
M6 x 18 Flange bolt : 2 pcs.
M6 x 14 Flange bolt : 6 pcs.
M6 bolt : 1 pc.
CONTROL BOX
BLOWER HOUSING
M6 FLANGE BOLT
M6 FLANGE
BOLT
STEP 7