Specifications & Performance Claims - Whirlpool WHELJ1 Installation And Operation Manual

Whirlpool central water filtration system
Table of Contents

Advertisement

Specifications & Performance Claims
This system has been tested according to NSF/ANSI 42 for the reduction of chlorine taste and odor. The concentra-
tion of the indicated substance in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI 42.
While testing was performed under standard laboratory conditions, actual performance of the system may vary
based on local water conditions.
Rated Service Flow Rate
Pressure Drop at Rated Service Flow
Pressure Drop at 9.6 gpm
Water Pressure Limits (minimum / maximum)
Water Temperature Limits (minimum / maximum)
Drain Flow Rate
Rated Capacity at Chlorine Concentration** of: 1.0 ppm
Sediment Removal with 30-40 micron particle size
Sediment Removal with 40-50 micron particle size
*
From independent laboratory test data.
**
Typical residential chlorine concentration is 0.5 to 1.0 ppm.
This system conforms to NSF/ANSI Standard 42 for the specific performance claims
as verified and substantiated by test data.
Substance
Chlorine
Questions? Call Toll Free 1-866-986-3223
When you call, please be prepared to provide the model and serial number,
SPECIFICATIONS
PERFORMANCE CLAIMS
Influent
Challenge Level
2.0 ±10% mg/L
or visit www.whirlpoolwatersofteners.com
located on the rating decal on back of the cover.
Model WHELJ1
6.0 gpm (22.7 L/min.)
10 psig
15 psig
(206.8 - 861.8 kPa)
40 - 100 °F (5 - 38 °C)
0.50 ppm
0.75 ppm
1.5 ppm
2.0 ppm
Reduction
Average Percent
Requirement
50%
Monday- Friday, 8 AM - 7 PM EST
3
*
(68.9 kPa)
*
(103.4 kPa)
30 - 125 psi
3.4 gpm
2,280,000 gal.*
1,520,000 gal.*
1,140,000 gal.*
760,000 gal.*
570,000
gal.*
95% or more
99% or more
Removal
82.8%