Alignment and Adjustment
b. Connect a power source.
c. Get into the VCR adjustment mode.
d. Press the "DATE/TIME(MODE UP)/TITLE
(MODE DOWN)" button of CAMCORDER so
as to select the address 19.
e. Press the "C/RESET(DATA UP)/Z/RTN(DATA
DOWN)" so that OSD shows "ERR:XX EVR:
XX" "XX" is different dependent on the model
as below.
MODEL NAME
ADDRESSED CODE
VP-A30
30
VP-A31
31
VP-A33
33
VP-A34
34
VP-A800
80
VP-A850
85
f. Be sure to press the "MENU/ENTER(CON-
FIRM)" button of CAMCORDER to memorize
setting.
g. Reset the power source so as to fix the new data
to the camcorder's EEPROM.
2-2. Head Switching Point
: This adjustment is performed after the
replacement of deck mechanism.
• Without this adjustment, there will be a noise
in playback picture.
a. Preparations
STANDARD COLOR BAR TAPE
RECORDED WITH SP SPEED
TAPE
EQUIPMENT
POWER SOURCE
OTHER
NONE
TEST POINT
NONE
ADDRESS
0A
NAME
HD SWP
b. Connect a power source.
c. Get into the VCR adjustment mode.
d. Press the "DATE/TIME(MODE UP)/TITLE
(MODE DOWN)" button of CAMCORDER so
as to select the address 0A.
e. Insert the Standard Color Bar Tape and press
the PLAY button.
5-34
MODEL NAME
ADDRESSED CODE
SCA30
30
SCA31
30
SCA33
33
SCA35
35
SCA80
80
SCA85
85
Note : If there is no video out, when you pressed
the PLAY button, you can not adjust the
Head Switching Point.
It may be caused by maladjusted VIDEO
block.
In this case, adjust the VIDEO block before
the Head Switching Point.
VIDEO block adjustments are 2-3~2-11.
f. The data of Head Switch is set to 6.2H~6.7H
automatically.
0A.HD SW P
EPR : XX
g. Be sure to press the "MENU/ENTER(CON-
FIRM)" button of CAMCORDER to memorize
setting.
h. Reset the power source so as to fix the new data
to the camcorder's EEPROM.
2-3. Adjusting Color Bar Level
: This adjustment is performed to set the stan-
dard level of color bar signal which is generat-
ed internally.
a. Preparations
TAPE
NONE
EQUIPMENT
OSCILLOSCOPE
OTHER
NONE
TEST POINT
IC201 PIN 24
ADDRESS
1C
NAME
COLOR BAR LEVEL
b. Connect a power source.
c. Get into the VCR adjustment mode.
d. Press the "DATE/TIME(MODE UP)/TITLE
(MODE DOWN)" button of CAMCORDER so
as to select the address 1C.
e. Connect the oscilloscope to the addressed Test
Point.
f. Press the "C/RESET(DATA UP)/Z/RTN(DATA
DOWN)" button so as to set the P-P level of
composite to 0.5V±0.02Vp-p.
Note : The level is changed after the confirmation.
6.5H