Download Print this page

Samsung SCL300 Service Manual page 62

8mm camcorder

Advertisement

2-13. Audio Deviation 1.5MHz (Hi8)
: This adjustment is performed to set the
1.5MHz deviation of the audio recording
processor and the adjustment perform in play-
back mode.
If the audio output level is 1Vp-p, the devia-
tion is to be a regulated deviation.
a. Preparations
STANDARD COLOR BAR TAPE
TAPE
(MONAURAL)
EQUIPMENT
DC POWER SUPPLY, OSCILLOSCOPE
OTHER
TEST POINT
CN605 PIN 10
ADDRESS
08
NAME
AUDIO DEV-1.5M
b. Connect a power source.
c. Get into the VCR adjustment mode.
d. Press the ÒTITLE (MODE UP)/DATE/TIME
(MODE DOWN)Ó button of CAMCORDER so
as to select the address 08.
e. Insert the Standard Color Bar Tape(monaural)
and press the PLAY button.
f. Connect the oscilloscope to the addressed Test
Point.
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Samsung Electronics
14
AUDIO OUT R
13
VIDEO OUT
12
AUDIO OUT R
11
PB RF
10
AUDIO OUT L
9
HD SW
8
VCR UNREG
7
JIG CS
6
VCR UNREG
5
JIG SCK
4
SS GND
3
JIG SO
2
JIG DETECT
1
JIG SI
g. Press the ÒEDIT + (DATA UP)/EDIT Ð (DATA
DOWN)Ó button so as to set the waveform to
be as below.
h. Be sure to press the ÒMENU/ENTER(CON-
FIRM)Ó button of CAMCORDER to memorize
setting.
i. Reset the power source so as to fix the new data
to the EEPROM.
Alignment and Adjustment
5-41

Advertisement

loading