The touch control section consists of the following units as
shown in the touch control panel circuit.
(1) Key Unit
(2) Control Unit
The principal functions of these units and the signals com-
municated among them are explained below.
Key Unit (R-330AK / AW)
The key unit is composed of a matrix, signals generated in
the LSI are sent to the key unit through P36, P35, P34, P33,
P27, P26, P25 and P24.
When a key pad is touched, a signal is completed through
the key unit and passed back to the LSI through P20 - P23
to perform the function that was requested.
Key Unit (R-310AK )
The key unit is composed of a matrix, signals generated in
the LSI are sent to the key unit through P73, P81, P82, P83,
P90 and P91.
When a key pad is touched, a signal is completed through
the key unit and passed back to the LSI through P60 - P63
to perform the function that was requested.
Control Unit
Control unit consists of LSI, ACL circuit, indicator circuit,
power source circuit, relay circuit, buzzer circuit, synchro-
nizing signal circuit, absolute humidity sensor circuit and
back light circuit.
1) ACL
This circuit generates a signal which resets the LSI to the
initial state when power is supplied.
2) Indicator Circuit (R-330AK / AW)
This circuit consists of 25 segments and 4 common
electrodes using a Liquid Crystal Display.
TOUCH CONTROL PANEL ASSEMBLY
OUTLINE OF TOUCH CONTROL PANEL
Indicator Circuit (R-310AK)
This circuit consists of 12 segments and 3 common
electrodes using a Liquid Crystal Display.
3) Power Source Circuit
This circuit generates voltages necessary in the control
unit from the AC line voltage.
In addition, the synchronizing signal is available in order
to compose a basic standard time in the clock circuit.
Symbol
Voltage
VC
-5V
4) Relay Circuit
A circuit to drive the magnetron, fan motor, turntable
motor and light the oven lamp.
5) Buzzer Circuit
The buzzer is responsive to signals from the LSI to emit
audible sounds (key touch sound and completion sound).
6) Synchronizing Signal Circuit
The power source synchronizing signal is available in
order to compose a basic standard time in the clock
circuit.
It accompanies a very small error because it works on
commercial frequency.
7) Door Sensing Switch
A switch to "tell" the LSI if the door is open or closed.
8) Back Light Circuit
A circuit to drive the back light (Light emitting diodes
LD1- LD5).
9) Absolute Humidity Sensor Circuit (R-330AK / AW)
This circuit detects moisture of the cooking food to allow
its automatic cooking.