Sharp UX-68 Service Manual page 24

Hide thumbs Also See for UX-68:
Table of Contents

Advertisement

UX-68DE
FO-78DE
SW-I7 No. 5 ~ No. 8 Reserved
Set to "0".
SW-I8 No. 1 ~ No. 5 OGM/ICM output level
(0~-31dBm setting by 1dBm step)
Used to control OGM and ICM output level.
SW-I8 No. 6 AM OGM announce only mode
If this switch is set to 1, the machine is not recording ICM.
(disconnect the line after OGM output)
SW-I8 No. 7, No. 8 Reserved
Set to "0".
SW-J1 No. 1 Sender's phone number setting
Used to make a choice of whether the registered sender's phone number
can be changed or not. If the switch is set to "1", new registration of the
sender's phone number is disabled to prevent accidental wrong input.
SW-J1 No. 2 Summer time setting
Used to set YES/NO of automatic clock adjustment for Summer time.
SW-J1 No. 3, No. 4 Ringer Volume
Used to adjust ringing volume.
SW-J1 No. 5, No. 6 Reserved
Set to "0".
SW-J1 No. 7 Polling key
If this switch is set to 1, the last of Rapid key works as polling key.
SW-J1 No. 8 Reserved
Set to "0".
SW-J2 No. 1, No. 2 Reserved
Set to "0".
SW-J2 No. 3 ~ No. 5 Speaker Volume
Used to adjust sound volume from a speaker.
SW-J2 No. 6 Speaker monitor function
Used to select whether to make the speaker monitor function valid or
not.
SW-J2 No. 7 Saving energy start timing
Used to set the time between the machine's stand-by state (clock indi-
cation) after operation and saving energy mode.
It is possible to set the time to either 5 sec or 180 sec (default).
SW-J2 No. 8 Saving energy mode
Used to select whether to make the saving energy mode valid or not.
SW-J3 No. 1 ~ No. 3 Communication results printout
(Transaction report)
It is possible to obtain transaction results after each communication.
Normally,the switch is set (No. 1 : 0, No. 2 : 0, No. 3 : 0) so that the
transaction report is produced only when a communication error is en-
countered.
If No.1 was set to 0 and No. 2 to 1 and No. 3 to 0, the transaction report
will be produced every time a communicaion is done, even if the
communicaion was successful.
Setting No. 1 to 0 and No. 2 to 1 and No. 3 to 1 will disable this function.
No transaction report printed.
SW-J3 No. 4 Time format
When set to "0", 24hour time format is used.
When set to "1", 12hour time format is used.
SW-J3 No. 5 Date format
When set to "0", Day-Month-Year format is used.
When set to "1", Month-Day-Year format is used.
SW-J3 No. 6 ~ No. 8 Reserved
Set to "0".
SW-K1 No. 1 Entering diag mode by pressing SPEED key
A bit which is used in the production process only. When the SPEED key
is pressed, the switch is changed from the stand-by state to the diag
mode.
SW-K1 No. 2 ~ No. 8 Reserved
Set to "0".
2 – 18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fo-78

Table of Contents