Further details regarding the individual steps
Language selection (if necessary)
only with Comfortrol menu-assisted programming unit
SPRACHE/LANGUAGE
>DEUTSCH:.........A
>ENGLISH:.........B
>ZURÜCK/BACK:....D
Checking the gas type
¨ Safety instruction
The natural gas version cannot be converted to LPG.
1.
Please note:
In the "as delivered condition",
Vitodens 200 is set up for natural
gas E or LPG P .
Natural gas E version:
The boiler can be operated in the
Wobbe index range 12.0 to
3
16.1 kWh/m
(43.2 to 58.0 MJ/m
LPG P version:
The boiler can be operated in the
Wobbe index range 21.4 to
3
22.5 kWh/m
(76.9 to 81.0 MJ/m
2.
³
³
³
3.
After conversion from
H natural gas E or LPG P to natural
gas LL
3
).
The boiler can be operated in the
Wobbe index range 10.0 to
13.1 kWh/m
H LPG P to natural gas E
The boiler can be operated in the
3
).
Wobbe index range 12.0 to
16.1 kWh/m
4.
See separate conversion
kit installation instructions.
3
(36.0 to 47.2 MJ/m
3
(43.2 to 58.0 MJ/m
D
A
C
3
).
3
).
7