1.3

Details of Maintenance Mode Functions

1.3.1 Initialize EEPROM parameters (function code: 01, 91)

<Function>
This function is used to initialize the setting values for operation parameters, user switches,
and worker switches (WSW) registered in the EEPROM. Entering function code 01 initializes
most EEPROM areas. Entering function code 91 initializes only the specified areas as shown
in the table below.
Data item
Printer switch (counter information)
Error history
MAC address
Password for control panel operation lock
Secure function lock
Telephone function registration
Telephone directory
Worker switches
User switches (items initialized when
"Factory Reset" is executed)
Function settings except user switches
(settings not subject to "Factory Reset")
LAN setting
Emulation setting
<Operation Procedure>
(1) Press the [0] and [1] buttons in this order in the initial state of maintenance mode to display
"Maintenance 01" (or press the [9] and [1] buttons as appropriate to display "Maintenance
91") on the LCD.
(2) Press the [OK] button. "PARAMETER INIT" is displayed on the LCD.
(3) When initializing parameters is completed, the machine returns to the initial state of
maintenance mode.
Function code
Areas not to be
initialized
Areas to be
initialized
5-3
01
91
Areas not to be
initialized
Areas to be
initialized