Description
3 BOILER WITH TANK (INTERNAL OR EXTERNAL) AND SOLAR APPLIANCE CONNECTION
3 0 GENERAL SETTING
3 0 0
NOT ACTIVATED
3 0 1
NOT ACTIVATED
3 0 2
NOT ACTIVATED
3 1 Entering access code
3 2 SPECIAL SETTING
3 2 0 Anti-legionella function
This function avoids the formation of the legionella bacterium wich sometimes develops in pipes and water tanks where the temperature is
included between 0 and 40°C. If the storage temperature remains more than 100 hours less than 59°C and the function is enable, the boiler
is light aan and the storage water is warmed up to 65°C during 30 minutes.
3 2 1 NOT ACTIVATED
3 2 2 NOT ACTIVATED
3 2 3 Collector delta temp pump ON
3 2 4 Collector delta temp pump OFF
3 2 5 Minimum collector temp pump ON
2 2 6 Collector kick
3 2 7 Recooling function
3 2 8
NOT ACTIVATED
3 2 9 Collector frost protection temperature
36
value
0=OFF - 1 = ON
from 0 to 30°C
from 0 to 30°C
from 10 to 90°C
ON or OFF
ON or OFF
from -0 to +5°C
 Turn the encoder clockwise to select 34 and
press the m
button
enu
8

Enable only with Clip-In solar connected
30