iMpOrTanT inSTrUCTiOnS

When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock
and injury to person, including the following:
1.
Read all instructions before using this heater.
2.
A heater has hot and arcing or sparking parts inside. Do
not use it in areas where gasoline, paint or flammable
liquids are used or stored.
3.
This heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces. If provided, use handles
when moving this heater. Keep combustible materials
such as: furniture, pillows, bedding, papers, clothes and
curtains away from heater.
4.
To prevent a possible fire, do not block air intakes or
exhaust in any manner. Do not use on soft surfaces like
a bed where openings may become blocked.
5.
Do not insert or allow foreign objects to enter any venti-
lation or exhaust opening as this may cause an electric
shock or fire, or damage the heater.

SavE THESE inSTrUCTiOnS

installation instructions

Warning: Wiring procedures and connections should
be in accordance with the National Electric code (NEC) and
local codes.
HEaTEr LOCaTiOn
Unit heaters should be located along outside walls to provide
perimeter air circulation. The discharge air should wipe the
walls without blowing directly on them. (Figure 1)
Small rooms
- can be heated by one or two units.
Locate the unit heater(s) to set up circular air movement
within the space.
Large rooms
- requiring multiple unit installations. Units
should be located so that the discharge air from one unit
supports the discharge from another unit and sets up a
circular movement.
remove Thermostats
walls or posts away from heat sources, cold drafts, and
away from heater discharge air streams.
MOUnTing UniT HEaTEr(S)
Heater should be mounted a minimum of ten (10) inches
from walls and six (6) feet above floor with discharge parallel
to or away from wall.
Ceiling Mounting
- The heater comes equipped with a
mounting bracket. Fasten to or suspend the heater from
the ceiling using the holes provided in the bracket.
Wall Mounting
- The heater may also be mounted to a
wall with accessory wall bracket, catalogue 39005534.
The wall bracket attaches to the centre hole of unit
mounting bracket.
- should be located on interior
Wiring

W arning: BE SURE ELECTRICITY IS TURNED OFF
AT MAIN SWITCH BEFORE WIRING. ALL WIRING TO
BE IN ACCORDANCE WITH LOCAL AND NATIONAL
ELECTRIC CODES. HEATER MUST BE GROUNDED
AS A PRECAUTION AGAINST ELECTRIC SHOCK.
1.
Connect heater only to the voltage and frequency
specified on the nameplate.
2.
All wiring to be inaccordance with local codes and
National Electrical Code.
3.
Remove screws securing access door and swing door
down to expose wiring and control compartment.
4.
Knockouts are provided at the back of and one side
of the heater for power and control wiring. (Figure 2)
Combination 1 3/8" and 1 1/8" and 1 1/8" and 7/8".
5.
A ground terminal is provided. The ground wire should
be connected before making other connections.
6.
Rough-in branch circuit wiring to the heater using
wire rated for 60 C. Wire heater according to diagram
attached to the access door.
7.
Electrical accessory options are shown on the heater
wiring diagram connected by a dashed line.
Figure 1
EXpOSED OUTSiDE WaLL
SMaLL rOOM
EXpOSED OUTSiDE WaLL
Operation
COnTrOLS
Fan Delay -
The heater is equipped with a fan delay
control. There will be a short delay to enable the heating
elements to warm up before the fan turns on. The fan
will also remain on for a few moments after the elements
are de-energized.
automatic High Limit
automatic reset thermal cutouts. Should these safety
switches operate, they will automatically reset once
the element reaches a safe operation temperature,
however, the cause of the high limit condition should be
determined and corrected to sure satisfactory operation.
LargE rOOM
- Each heater is equipped with
7202460001R02

Advertisement

loading

Summary of Contents for Dimplex EUL-B Series

  • Page 1: Important Instructions

    Electric Unit Heaters EUL-B & EUS-B Series Wiring iMpOrTanT inSTrUCTiOnS W arning: BE SURE ELECTRICITY IS TURNED OFF When using electrical appliances, basic precautions should AT MAIN SWITCH BEFORE WIRING. ALL WIRING TO always be followed to reduce the risk of fire, electric shock BE IN ACCORDANCE WITH LOCAL AND NATIONAL and injury to person, including the following: ELECTRIC CODES.
  • Page 2 Any claims under this Warranty must be submitted The special control terminal block is utilized for this in writing to the Service Manager, Dimplex North America Ltd., 1367 optional control feature. Industrial Rd., Cambridge, Ontario N1R 7G8, Canada.

This manual is also suitable for:

Eus-b series