Nordyne O4MD Installation, Operation And Maintenance Manual page 17

Oil fired downflow/horizontal warm air furnace
Table of Contents

Advertisement

Table A-1 Beckett AF Oil Burner Set-Up
BECKETT
AF SERIES
OIL
BURNERS
I
Appendix A
FURNACE
OUTPUT
BURNER
PUMP
STATIC
NOZZLE
FLOW RATE
HEAD
MODEL
BTUH
MODEL
PRESSURE
PLATE
59,000
AF76BO
0.50 / 60°A
100 PSIG
0.50 U.S.GPH
F0
3-3/8"
O4MD-091A-
12-F
77,000
AF76BO
0.65/60°A
100 PSIG
0.65 U.S.GPH
F0
3-3/8"
88,000
AF76XN
0.75 / 60°A
100 PSIG
0.75 U.S.GPH
F3
2-3/4"
91,000
AF76XN
0.75 / 80 ° A
100 PSIG
0.75 U.S.GPH
F3
2-3/4"
O4MD-140A-
101,000
AF76XN
0.85 / 80 ° A
100 PSIG
0.85 U.S.GPH
F3
2-3/4"
16-F
117,000
AF76XN
1.00 / 60 ° A
100 PSIG
1.00 U.S.GPH
F3
2-3/4"
128,000
AF76YB
1.10 / 70 ° A
100 PSIG
1.10 U.S.GPH
F6
2-3/4"
In the United States, the Beckett AF Burner may be equipped with Beckett's "Inlet Air Shut-Off' to increase efficiency. (Beckett Part No. AF/A 5861).1t reduces the
amount of air passing through the oil burner, combustion chamber, breaching, etc. up the chimney between burner cycles.
NOTE: Use of the inlet air shut-off could cause post combustion nozzle drip.
FURNACE
MBH
60
8O
90
90
100
120
130
BLOWER
GT-10
11-10T
Table A-2 Direct Drive Blower Set-Up
BLOWER SET-UP
0.20 in. w.c.
0.50 in. w.c.
SPEED
MOTOR
MOTOR
1/2 HP
Low
Medium-Low
Medium-High
1/2 HP
SPEED
O4MD-091A-12-F
Medium-Low
Medium-High
High
O4MD-140A-16-F
Medium-High
Medium-High
High
High
1/2 HP
1/2 HP
TONS
2-3
Medium-Low
Medium-Low
Medium-High
Medium-High
3-4
COOLING CAPACITY
MOTOR
CFM RANGE
1/2 HP
1/2 HP
690-1210
1000-1500
I
]7
153B0801

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

O4md-091a-12-fO4md-140a-16-f