Nordyne O4MD Installation, Operation And Maintenance Manual page 14

Oil fired downflow/horizontal warm air furnace
Table of Contents

Advertisement

Annual Service By Contractor
THE
COMBUSTION
CHAMBER
(FIREPOT)
IS
FRAGILE.
USE CARE
WHEN
INSPECTING
AND
CLEANING THIS AREA.
The heat exchanger should be inspected periodically and
cleaned
if necessary,
if cleaning
is necessary,
SHUT
OFF POWER
TO THE FURNACE
and remove
the
burner. Using a stiff brush with a wire handle, brush off
scale and soot from inside the drum and flue pipe. To
clean the radiator, remove the round covers on the inner
front panel to gain access to the cleaning ports. When
this procedure is done for the first time, carefully cut away
the insulation covering the opening with a sharp knife.
Loosen the nuts on the radiator clean-outs.
DO NOT
REMOVE THE NUTS. Remove the covers carefully to
avoid tearing the gaskets. A wire brush can be used to
loosen
dirt and debris
on the inside surfaces
of the
radiator. Clean out all accumulated dirt, soot and debris
with a wire handled
brush and an industrial
vacuum
cleaner. Before replacing the clean-out covers, inspect
the gaskets.
If the gaskets
are broken,
remove
the
remnants
and
replace
with
new gaskets.
Snug
the
cleanout covers. DO NOT OVER-TORQUE
THE CLEAN-
OUT NUTS. Replace
the inner front panel clean-out
covers.
NOTE:
A
radiator
clean-out
assembly
inadvertently
dropped into the interior of the furnace can usually be
easily retrieved with a magnet on a wire handle or with a
magnet tied to a string.
Both the direct drive blower motor and oil burner motor
are factory sealed. They do not require annual lubrication.
Inspect the blower fan. Clean if necessary.
Oil Burner Maintenance: Follow the instructions of the oil
burner
manufacturer.
(See oil burner
manufacturer's
instructions
supplied
with furnace).
It is advisable
to
change the oil burner nozzle and oil filter on an annual
basis.
The venting system should be cleaned and inspected for
signs of deterioration.
Replace pitted or perforated vent
pipe and fittings.
The barometric
damper should open
and close freely.
All electrical connections
should be checked to ensure
tight connections.
Safety controls such as the high limit
controls should be tested for functionality. The fan control
should be checked to ensure that the "fan off" function
continues to stop the blower fan at temperatures between
90°F to 100°F.
[_WARNING[
DO NOT
ATTEMPT
TO
START
THE
BURNER
WHEN
EXCESS
OIL
HAS
ACCUMULATED,
WHEN
THE FURNACE
IS FULL
OF VAPOUR,
OR WHEN
THE
COMBUSTION
CHAMBER
IS
VERY
HOT.
NEVER
BURN
GARBAGE
OR
PAPER
IN THE FURNACE,
AND NEVER
LEAVE
PAPER OR RAGS AROUND
THE UNIT.
14
153B0801