2.1.4 Switch Upper Panel

The Upper Panel of the Industrial Managed Switch indicates a DC inlet power socket and consist one terminal block
connector within 6-contacts. It accepts input power from 12 to 48V DC and 24V AC.
1.
Insert positive / negative DC power wires into contacts 1 and 2 for DC Power 1, or 5 and 6 for DC Power 2.
2.
Tighten the wire-clamp screws for preventing the wires from loosening.
1. The wire gauge for the terminal block should be in the range of 12 ~ 24 AWG.
2. When performing any of the procedures like inserting the wires or tighten the wire-clamp screws,
make sure the power is OFF to prevent from getting an electric shock.
Figure 2-3: IGS-20040MT Upper Panel
1
2
3
DC 1
+
-
Figure 2-4 6-Pin Terminal Block Power Wiring Input
26
User's Manual of IGS-20040MT
4
5
6
DC 2
+
-