Electrical Adjustment

Service Adjustment Data Table

GROUP NO. ITEM
0
Temperature Monitor Indication
0 LM76 (Temp) Monitor (°C)
1 LM76 (Temp) Monitor (°C)
2 Thermistor Monitor (°C)
3 Thermistor Monitor
1
Pressure Monitor Indication
0 MPXA4114A(Pressure) Monitor
1 MPXA4114A(Pressure) Monitor
2 MPXA4114A(Pressure) Monitor
4
Flow Sensor Monitor (Read only)
0 Flow Sensor Monnitor
10
RS232C Set
0 Baud rate
11
PJ-Net Set
0 Reset Disable
20
Logo On/Off
0 Logo On/Off
30
Color Shading / Gamma Correction
0 Color shading Correction On/Off
1 Gamma Correction On/Off
40
Dimmer Control
0 Dimmer On/Off
1 Dimmer Level LAMP1
2 Dimmer Level LAMP2
3 Dimmer Level LAMP3
4 Dimmer Level LAMP4
50
Auto Picture Control
0 Auto Picture On/Off
80
Projector Time
0 Projector Time Reset
91
Projector Error Logs History
0 Warning_Log_1
~
:
49 Warning_Log_50
50 Warning_Log_Reset
100
Shutter Operation
0 PRE_MOTION
1 CMP_TRM
2 OUT_DLY_TRM
3 CMP_CHK_CNT
4 OPEN_DLY
5 CLOSE_DLY
113
Reset Frequency Counter
0 Lamp 1
1 Lamp 2
2 Lamp 3
3 Lamp 4
115
Lamp Go Out
0 Lamp Go Out
116
Lamp Replace Display
0 Lamp Replace Display
117
Lamp Life Test
0 Lamp Life Test Enable
1 Lamp Om time
2 Lamp Off time
3 Lamp Total time
130
75 ohm Terminate / Analog filter
These initial values are the reference data written from the
CPU ROM to memory IC when replaced new memory IC. The
adjustment items indicated with "✻" are required to readjust fol-
lowing to the "Electrical adjustments". Other items should be
used with the initial data value.
FUNCTION
Temp. Sensor (Intake)
Temp. Sensor (Inner)
Temp. Thermistor (Inner)
DAC value
Pressure Sensor
Pressure Sensor (mmHg)
Pressure Sensor (hpa)
Flow Sensor
RS232C Baud rate (0 : 19200 / 1 : 9600)
PJ-Net Reset (0 : Enable / 1 : Disable)
(0 : Menu Operation / 1 : Prohibition)
(0 : Off / 1 : On) Not memorized
(0 : Off / 1 : On) Not Memorized
(0 : Menu Operation / 1 : Off)
(0 : 264W ~ 15 : 330W)
(0 : 264W ~ 15 : 330W)
Not used
Not used
(0 : Menu Operation / 1 : Off)
Latest Error Log
50th older Error Log
Resets the logs when the value set to 10.
Pre-Motion Enable (o: Enable, 1: Disable)
Chattering Detection Time
Output Time
Detetion Count
Open Delay Time
Close Delay Time
Lamp 1 Total Lighting Time
Lamp 2 Total Lighting Time
Not used
Not used
0 : Disable / 1 : Enable
0 : Disable / 1 : Enable
0: Disable / 1: Enable For safety test
-70-
RANGE
INITIAL VALUE
0 / 1
0
0 / 1
0
0 / 1
0
0 / 1
1
0 / 1
1
0 / 1
1
0 ~ 15
15
0 ~ 15
15
0 ~ 15
0 ~ 15
0 / 1
1
0 ~ 10
0
0 ~ 32767
0
:
:
0 ~ 32767
0
0 ~ 10
0
0 ~ 1
0
0 ~ 65535
0
0 ~ 65535
0
0 ~ 15
0
0 ~ 63
0
0 ~ 63
0
0 ~ 127
0
0 ~ 127
0
0 ~ 127
0 ~ 127
0 / 1
0
0 / 1
1
0
1
3
0
NOTE