York AM012M1021 Technical Manual

York AM012M1021 Technical Manual

Split-system air conditioners 10 seer (1 thru 2.5 nominal tons, 1 ph)

Advertisement

TECHNICAL GUIDE
SPLIT-SYSTEM
AIR CONDITIONERS
10 SEER
AM012M102 THRU AM030M1021
(1 THRU 2.5 NOMINAL TONS, 1 PH)
This product was manufactured
Certification applies only
in a plant whose quality system
when the complete
is certified/registered as being
system is listed
in conformity with ISO 9001.
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ariprimenet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
®
R
P
LISTED
with ARI.
DESCRIPTION
The 10 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be cus-
tom-matched with one of UPG's complete line of evaporator
sections, each designed to serve a specific function. Match-
ing air handlers are available for upflow, downflow, or hori-
zontal applications to provide a complete system. Electric
heaters are available if required. Add-on coils are available
for use with upflow, downflow, or horizontal furnaces and air
handlers.
WARRANTY
5-year limited parts warranty.
5-year limited compressor warranty.
FEATURES
• QUALITY CONDENSER COILS - The coil is constructed
of enhanced copper tube and aluminum fins.
• COIL PROTECTION - Coils are protected from damage by
a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.
• PROTECTED COMPRESSOR - Recip compressors are
internally protected against high pressure and tempera-
ture. This is accomplished by the simultaneous operation
of high pressure relief valve and a temperature sensor
which protects the compressor if undesirable operating
conditions occur. A liquid line filter-drier further protects the
compressor.
• DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated flat galvanized steel provides a bet-
ter paint-to-steel bond, which resists corrosion and rust
creep. Special primer formulas and matted desert sand fin-
ish insure less fading when exposed to sunlight.
• LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connec-
tions. The unit contains enough refrigerant for matching
indoor coils and 15 feet of interconnecting piping. The
small base dimension means less space is required on the
ground or roof.
• TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
• LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise up away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.
• LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
• EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections and a single panel covering the electrical controls
make for easy servicing of the unit.
• SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
• U.L. AND C.U.L. LISTED - Approved for outdoor applica-
tion.
Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.
036-21573-001 Rev. A (0304)

Advertisement

Table of Contents
loading

Summary of Contents for York AM012M1021

  • Page 1 • U.L. AND C.U.L. LISTED - Approved for outdoor applica- are subject to change without notice. tion. Visit us on the web at www.york.com for the most Certified in accordance with the Unitary Small Equipment cer- up-to-date technical information. tification program, which is based on ARI Standard 210/240.
  • Page 2: Physical And Electrical Data

    036-21573-001 Rev. A (0304) Physical and Electrical Data MODEL AM012M1021 AM018M1021 AM024M1021 AM030M1021 Unit Supply Voltage 208-230V, 1φ, 60Hz 187 to 252 Normal Voltage Range Minimum Circuit Ampacity 10.1 15.3 19.3 Max. Overcurrent Device Amps Compressor Type Rotary Recip Recip...
  • Page 3 036-21573-001 Rev. A (0304) Additional R-22 Charge / Orifice Size for Various Matched Systems ADDITIONAL R-22 CHARGE / ORIFICE SIZE FOR VARIOUS MATCHED SYSTEMS Outdoor Unit AM012M1021 AM018M1021 AM024M1021 AM030M1021 Unit Orifice (s) Factory R-22 Charge, lbs-oz 3 - 2...
  • Page 4: Sound Ratings

    UNIT MODEL NET MBH SEER RATED SEER ELECTRIC MODEL MODEL W/O TXV HEAT KW + TXV TOTAL SENS. 1 PH 10 SEER AC WITH N1AH / G2FD AM012M1021 N1AHB0806 G2FD024(S,H)17 14.5 10.4 10.00 10.00 AM018M1021 N1AHB0806 G2FD024(S,H)17 18.6 13.4 10.00 9.50...
  • Page 5: Cooling Performance

    MODEL RATED CFM SEER + TXV (MIN.-MAX.) W/O TXV TOTAL SENS. 14,17 G1FA024S14,17 14.4 10.3 10.00 9.95 G1HD024 14.6 10.4 10.00 10.00 AM012M1021 G1NA024S17G 14.1 10.0 10.00 9.80 14,17 G1UA024S14,17 14.4 10.3 10.00 9.95 14,17 G2FD024(S,H)14,17 14.5 10.4 10.00 10.00...
  • Page 6: Typical Installation

    036-21573-001 Rev. A (0304) TYPICAL INSTALLATION THERMOSTAT TO FURNACE OR AIR HANDLER TERMINAL BLOCK MINIMUM 18” SERVICE ACCESS CLEARANCE ON ONE SIDE NEC CLASS 1 WIRING WEATHERPROOF DISCONNECT NEC CLASS 2 WIRING SWITCH 60” OVERHEAD CLEARANCE TO INDOOR COIL 6” CLEARANCE AROUND PERIMETER SEAL OPENING(S) WITH PERMAGUM OR EQUIVALENT...
  • Page 7: Cooling Performance Data

    036-21573-001 Rev. A (0304) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. AM012M1021 INDOOR COIL MODEL NO. G1NA024S17G ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 15.4 14.6 13.8 15.4 14.7 14.0 15.5 14.8 14.2 S.C.
  • Page 8 036-21573-001 Rev. A (0304) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. AM018M1021 INDOOR COIL MODEL NO. G1NA024S17G ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 20.6 19.1 17.8 20.7 19.5 18.3 20.9 19.9 18.8 S.C. 11.3 11.1 10.8...
  • Page 9 036-21573-001 Rev. A (0304) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. AM024M1021 INDOOR COIL MODEL NO. G1NA030S17H ID CFM 1050 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 28.0 26.3 23.9 28.3 26.6 24.7 28.5 27.0 25.5 S.C.
  • Page 10 036-21573-001 Rev. A (0304) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. AM030M1021 INDOOR COIL MODEL NO. G1NA030S17K ID CFM 1050 1250 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 32.8 31.3 29.0 33.2 31.8 29.9 33.7 32.3 30.7 S.C.
  • Page 11 036-21573-001 Rev. A (0304) MATCHING INDOOR COMPONENTS ADD-ON COILS - FOR FURNACE APPLICATIONS G1NA G1UA UNCASED G1HD 1/2 CASED UPFLOW HORIZONTAL DUCT UPFLOW G2FD* MULTI-POSITION G1FA (UPFLOW, HORIZONTAL FULL CASED AND DOWNFLOW) UPFLOW * Available with factory installed horizontal drain pan. AIR HANDLERS - FOR NON-FURNACE APPLICATIONS N-AH OR N-VS MODULAR BLOWER...
  • Page 12 NOTES Subject to change without notice. Printed in U.S.A. 036-21573-001 Rev. A (0304) Copyright © by York International Corp. 2004. All rights reserved. Supersedes: Nothing Unitary 5005 Norman Product York Group Drive 73069...

This manual is also suitable for:

Am024m1021Am018m1021Am030m1021

Table of Contents